Pbxsummary | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Configuring your SMDR
The Cisco UCM stores its Call Detail Records in a MSSQL database, however, the output is not enabled by default.
To enable the CDR output, the following 'Service' parameters need to be configured on the Publisher, using the Service Parameters Configuration window:
- CDR Enabled
- CDR Log CallsWith Zero Duration Flag
- Call Diagnostics Enabled
The database that TIM Plus will connect to is called 'CDR'. Within this database there is a table called 'CallDetailRecord'. Rather than TIM Plus reading and removing data from the 'CallDetailRecord' table we highly recommend that you setup a second table which is a replication of the 'CallDetailRecord' table. This leaves the original table intact and can be used by other applications that may require it. There should be a SQL User already created with the following credentials:
- Username: CiscoCCMCDR
- Password: dipsy
To setup replication you will need to speak to your Database Administrator or your Cisco UCM maintainer. The replicated table name should be called 'calldetailrecord2'.
Please make sure that when the replication is setup that the above user has full access to the new table.
You will need to know the following information for TIM Plus to connect successfully to the Cisco UCM CDR database:
- IP/DNS of the MS SQL Database which is located on the Publisher.
- Username and Password to connect to the CDR database (you may need to speak to your maintainer about this).
HTML |
---|
<a id="info"></a> |
Setting up a DSN connection for TIM Plus
You will need to setup a DSN connection for TIM Plus to work with the Cisco UCM. Below you will find instructions on how to do this within Microsoft Windows:
- Click on Windows .
- Click on .
- Double click on icon.
- Double click on icon.
- Click on the tab.
- Click on the button.
- Select SQL Server from the list and click .
- In the Name field enter the following: CCM.
- In the Description field enter the following: TIM Plus link to CCM.
- In the Database name field enter the database type e.g SQL, MySQL etc.
- In the Server drop-down list select the Cisco UCM Publisher IP address or machine name.
- Click on the button.
- Click on the radio button With SQL Server authentication using a login ID and password entered by the user and click on the button.
- Click on the check box Change the default database to: and select CDR and then click on the button.
- Click on the button.
- Click on the button and once you make sure the test is completed successfully, click on the button.
- Now click on the button.
Now you will be able to see the CCM in the list.
An example of ODBC setup is shown below:
Screenshotmacro | ||||
---|---|---|---|---|
|
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Cisco UCM 4.0:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
HTML |
---|
<p>These instructions should assist in configuring your Cisco UCM to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.</p> <table class="confluenceTable"> <tbody> <tr> <th class="confluenceTh" width=158>Connection information</th> <th class="confluenceTh">Description</th> </tr> <tr> <td class="confluenceTd"><b>Connection type</b></td> <td class="confluenceTd">IP </td> </tr> <tr> <td class="confluenceTd"><b>IP method</b></td> <td class="confluenceTd">The Cisco UCM stores its Call Detail Records in a MS SQL database which is located on the <span class="reference">Publisher</span>. </td> </tr> </tbody> </table> <h2>Configuring Cisco Unified Call Manager</h2> <p>By default the CDRs are not written to the MS SQL Database. The following 'Service' parameters need to be enabled on the <span class="reference">Publisher</span> using the <span class="reference">Service Parameters</span> Configuration window:</p> <ul> <li>CDR Enabled</li> <li>CDR Log CallsWith Zero Duration Flag</li> <li>Call Diagnostics Enabled</li> </ul> <p>The database that TIM Plus will connect to what is called 'CDR'. Within this database there is a table called 'CallDetailRecord'. Rather than TIM Plus reading and removing data from the 'CallDetailRecord' table we <b>highly recommend</b> that you setup a second table which is a replication of the 'CallDetailRecord' table. This leaves the original table intact and can be used by other applications that may require it. There should be a SQL User already created with the following credentials:</p> <ul> <li><b>Username:</b> <span class="keyword">CiscoCCMCDR</span></li> <li><b>Password:</b> <span class="keyword">dipsy</span></li> </ul> <p>To setup replication you will need to speak to your Database Administrator or your Cisco UCM maintainer. The replicated table name should be called 'calldetailrecord2'.</p> <p>Please make sure that when the replication is setup that the above user has full access to the new table.</p> <p>You will need to know the following information for TIM Plus to connect successfully to the Cisco UCM CDR database:</p> <ul> <li>IP/DNS of the MS SQL Database which is located on the <span class="reference">Publisher</span>.</li> <li>Username and Password to connect to the CDR database (you may need to speak to your maintainer about this).</li> </ul> <h2>Setting up a DSN connection for TIM Plus</h2> <p>You will need to setup a DSN connection for TIM Plus to work with the Cisco UCM. Below you will find instructions on how to do this within Microsoft Windows:</p> <ol> <li>Click on Windows <span class="button no_margin">Start</span>.</li> <li>Click on <span class="button no_margin">Control panel</span>.</li> <li>Double click on <span class="button no_margin">Administrative tools</span> icon.</li> <li>Double click on <span class="button no_margin">Data Sources (ODBC)</span> icon.</li> <li>Click on the <span class="button no_margin">System DSN</span> tab.</li> <li>Click on the <span class="button no_margin">Add</span> button.</li> <li>Select <span class="reference">SQL Server</span> from the list and click <span class="button no_margin">Finish</span>.</li> <li>In the <span class="reference">Name</span> field enter the following: <span class="keyword">CCM</span>.</li> <li>In the <span class="reference">Description</span> field enter the following: <span class="keyword">TIM Plus link to CCM</span>.</li> <li>In the <span class="reference">Database name</span> field enter the database type e.g <span class="keyword">SQL</span>, <span class="keyword">MySQL</span> etc.</li> <li>In the <span class="reference">Server</span> drop-down list select the Cisco UCM Publisher IP address or machine name.</li> <li>Click on the <span class="button no_margin">Next</span> button.</li> <li>Click on the radio button <span class="keyword">With SQL Server authentication using a login ID and password entered by the user</span> and click on the <span class="button no_margin">Next</span> button.</li> <li>Click on the check box <span class="keyword">Change the default database to:</span> and select <span class="keyword">CDR</span> and then click on the <span class="button no_margin">Next</span> button.</li> <li>Click on the <span class="button no_margin">Finish</span> button.</li> <li>Click on the <span class="button no_margin">Test Data Source</span> button and once you make sure the test is completed successfully, click on the <span class="button no_margin">OK</span> button.</li> <li>Now click on the <span class="button no_margin">OK</span> button.</li> </ol> <p>Now you will be able to see the CCM in the <span class="button">System DSN</span> list.</p> <p>An example of ODBC setup is shown below:</p> <img class="screenshot" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/cisco_ucm_1.png" alt="Cisco UCM" /> <h2>Configuring TIM Plus</h2> <p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Cisco UCM 4.0:</p> <ol> <li>Browse to TIM Plus as normal and login with your credentials.</li> <li>Click on the <span class="button no_margin">Directory</span> tab.</li> <li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li> <img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/cisco_ucm_2.png" alt="Cisco UCM" /> <li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">Cisco UCM v4 DSN</span> from the <span class="reference">PBX model</span> drop-down list.</li> <li>In the <span class="reference">Connection method</span> field select <span class="keyword">Connect to a system DSN</span> from the drop-down list.</li> <li>In the <span class="reference">DSN name</span> field select <span class="keyword">Cisco UCM v4 DSN</span> from the drop-down list.</li> <li>In the <span class="reference">Frequency</span> field enter in <span class="keyword">5</span>.</li> <li>In the <span class="reference">DB script</span> field select <span class="keyword">Cisco UCM v4 DSN</span> from the drop-down list.</li> <li>Finally, click on the <span class="button no_margin">Save</span> button.</li> </ol> |