Pbxsummary
Supportfiles1Alcatel OmniPCX Enterprise.TDT
Supportfiles2Alcatel OmniPCX Enterprise.TDS
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Below you will find instructions on how to configure the SMDR output via a serial connection. These instructions are taken from the Alcatel OmniPCX Enterprise manual:

Connect to your PBX via telnet and follow the steps below:

  1. Applications (Enter)
  2. Accounting (Enter)
  3. Review/Modify (Enter)
  4. All Instance (F1)
  5. Realtime ticket Output: Set this to ethernet. Note that if you don't have appropriate license, you can only select V24 (serial) here.
  6. Save changes and exit

The table below presents a summary of data output from Alcatel:

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817041/alcatel_pbxs.png

HTML
<a id="Install NetPBX"></a>

Installing NetPBX

If your Alcatel OmniPCX Enterprise has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817042/alcatel_omnipcx_enterprise_2.png
  3. Within the Site Properties window, select Alcatel OmniPCX Enterprise from the PBX model drop-down list.
  4. In the Connection method field select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.