These instructions help you configure your Alcatel OmniPCX Office phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
RequiredTask4Configure TIM Plus
Supportfiles1Alcatel OmniPCX Office.TDT
Supportfiles2Alcatel OmniPCX Office.TDS
ConnectionDSN connection
RequiredTask1Configure the SMDR output
RequiredTask2Install Alcatel Office Link Driver
RequiredTask3Set up a DSN connection

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Below you will find instructions on how to configure the SMDR output for your Alcatel OmniPCX Office phone system.

Alcatel-Lucent OmniPCX Office Communication Server supports two types of call metering:

  • V24 metering supports V24 printing for all call metering tickets.
  • IP metering supports IP printing for call metering tickets originating from a 3rd party application (Business or Hotel) via an IP connection.

The type of metering must be specified when the Office Link driver is installed. The driver can be installed in one of two modes: hotel or metering. You can use the OMC Counting function to specify the type of call metering for hardcopy printouts.

To set printing options for call metering tickets, please follow the steps below:

  1. Open the Counting function window in the OMC console and select the Accounting Printouttab.
  2. Select the metering type from the drop-down box:  Ext. Accounting Activation IP or Ext. Accounting Activation V24 , and ensure that the associated checkbox is checked.
  3. When finished, click OK.

The table below presents a summary of data output from Alcatel:

Screenshotmacro
Borderfalse
URLhttp://178.32.50.115:8090/download/attachments/4817041/alcatel_pbxs.png

HTML
<a id="Install Alcatel Office Link Driver"></a>

Installing the Alcatel Office Link Driver

If your Alcatel OmniPCX Office has been configured to send SMDR data via IP, you will first need to install the Alcatel Office Link Driver to configure the output.

For information on how to install the Alcatel Office Link Driver, please refer to the Alcatel OmniPCX Office manual or speak to your phone maintainer.

HTML
<a id="Set up a DSN Connection"></a>

Setting up a DSN connection for TIM Plus

To get TIM Plus to work with the Alcatel Office Link Driver, you will need to setup a DSN connection . Below you will find instructions on how to do this within Microsoft Windows:

  1. Click on Windows Start.
  2. Click on Control panel.
  3. Double click on Administrative tools icon.
  4. Double click on Data Sources (ODBC) icon.
  5. Click on the System DSN tab.
  6. Click on the Add button.
  7. Select Native from the list and click Finish.
  8. In the Name field enter: TIM Plus - Alcatel OHL.
  9. In the Database name field enter: Native.
  10. Click on the OK button and then again to close the window.

Now you will be able to see the TIM Plus - Alcatel OHL in the System DSN list.

An example of ODBC setup is shown below:

Screenshotmacro
Borderfalse
URLhttp://178.32.50.115:8090/download/attachments/4817043/alcatel_omnipcx_office_1.png

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once the DSN connection has been setup, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties
    Screenshotmacro
    URLhttp://docs.call-logger.com:8090/download/attachments/4817043/alcatel_omnipcx_office_2.png
  3. Within the Site Properties window, select Alcatel OmniPCX Office from the PBX model drop-down list.
  4. In the Connection method field, select Connect to a system DSN from the drop-down list.
  5. In the DSN name field, select TIM Plus - Alcatel OHL from the drop-down list.
  6. In the Frequency field, enter in 5. This will check for data every five seconds.
  7. In the DB script field, select Alcatel OmniPCX Office OHL from the drop-down list.
  8. Cslick on the Save button to apply the settings.