Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

These instructions help you configure your NEC Aspire phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1NEC Aspire.TDT
Supportfiles2NEC Aspire.TDS
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPBX
Requiredtask2Configure TIM Plus
ConnectionSerial connection
or
Pbxsummary
Supportfiles1NEC Aspire.TDT
Supportfiles2NEC Aspire.TDS
Requiredtask1Configure the SMDR output
Requiredtask2Configure TIM Pus
ConnectionActive connection

Configuring your SMDR

Below you will find details on how to configure the SMDR output on the NEC Aspire. The programming will need to be done via PC Pro/Web Pro:

  1. Login to your PC Pro/Web Pro.
  2. As the NEC Aspire has multiple ways of sending SMDR data, below are the configuration settings based on each adaptor:

    AdaptorProgramming codeValueDescription
    NTCPU - IP10-12-01IP address that TIM Plus will connect to.NTUCPU Network Setup - IP Address.
    10-20-01TCP port that TIM Plus will connect to. We recommend using 9000 and increment it for each NEC Aspire you configure.LAN Setup for External Equipment.
    NTCPU - Serial10-21-021NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port, you have three options, 0(4800), 1(9600) and 2(38400).
    35-01-011SMDR Options - Output Port Type.
    CTA/CTU - Serial15-02-191Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module.
    15-02-201Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(19200).
    35-01-014SMDR Options - Output Port Type.
    35-01-02Extension number that the CTA/CTU adaptor is attached to.SMDR Options - Output Destination Number.
  3. You also need to configure the following programming codes:

    Programming codeValueDescription
    14-01-061Basic Trunk Data Setup - SMDR Print.
    15-01-031Basic Extension Data Setup - SMDR Print.
    35-01-030SMDR Options - Header Language.
    35-01-040SMDR Options - Omit (Mask) Digits.
    35-01-050SMDR Options - Minimum Number of SMDR Digits.
    35-01-060SMDR Options - Minimum Call Duration.
    35-01-070SMDR Options - Minimum Ringing Time.
    35-01-08DefaultSMDR Options - SMDR Format.
    35-02-010SMDR Output Options - Toll Restricted Call.
    35-02-021SMDR Output Options - PBX Calls.
    35-02-031SMDR Output Options - Display Trunk Name or Numbers.
    35-02-040SMDR Output Options - Daily Summary.
    35-02-050SMDR Output Options - Weekly Summary.
    35-02-060SMDR Output Options - Monthly Summary.
    35-02-081SMDR Output Options - Incoming calls.
    35-02-090SMDR Output Options - Print Name or Numbers.
    35-02-100SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-120SMDR Output Options - DID Table Name Output.
    35-02-131SMDR Output Options - CLI Output when DID to Trunk.
    35-02-141SMDR Output Options - Date.
    35-02-151SMDR Output Options - CLI/DID Number Switching.
    35-02-161SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-170SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18DefaultSMDR Output Options - Caller ID Name Output Method.
    80-05-011Date Format for SMDR and System Reports.

Serial output

HTML
<a id="info"></a>
Installing NetPBX

If your NEC Aspire has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817104/nec_aspire_2.png
  3. Within the Site Properties window, select NEC Aspire from the PBX model drop-down list.
  4. In the Connection method field select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

IP output

Configuring TIM Plus

If your NEC Aspire has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817104/nec_aspire_1.png
  3. Within the Site Properties window, select NEC Aspire from the PBX model drop-down list.
  4. In the Connection method field select Actively connect to PBX from the drop-down list.
  5. In the Host field enter the IP Address of your NEC Aspire.
  6. In the Port field enter in the port configured in programming code 10-20-01.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field select Generic Simple from the drop-down list.
  9. Finally, click on the Save button to apply the changes.

 

...

The NEC Aspire can be configured to send the SMDR data via a serial or an IP connection.  Click on one of the links below for your preferred connection method.