RequiredTask1Configure the Siemens
RequiredTask2Configure TIM Plus

HTML
 

Configuring your CIL output

CIL access over Ethernet

In addition to CIL access over V.24 ports, in all Realitis DX and iSDX systems with Software Revision 6.0 onwards, the System card or UPI card (Advanced Connectivity Interface (ACI)) allows remote access to the CIL stream over the Ethernet.

Tip

Note: Ethernet port address information is contained in this publication. If the information on how to set-up and activate this feature is required, a request must be made via Product Management at Beeston.

The CIL TCP server on the System/UPI cards allows a maximum of three concurrent connections from remote clientequipment (e.g. CILE). When the three connections are in use, subsequent connection requests are rejected.

Connecting to the CIL server

To gain connection to the CIL server on the System/UPI cards, it is necessary for the remote CILE to open a TCP/IP connection to the IP address of the active side DX. The connection request must contain the logical port number of the particular service required.

The DX System/UPI card TCP/IP address is specified by the variable "IPACT" in the permanent database, the local maintenance engineer would normally program this address.

The listening port is 17257.

Once a connection is established, the DX will begin sending packets to the connected client.