Configuring your SMDR output

Connect to your Avaya Communications Manager using an RS232 or IP terminal client and, after logging in with your administrative credentials, follow the steps below:

Configuring node-names ip

You will need to use the Issue the change node-names command to add a new node. You will have two fields which are required to be populatedTwo fields need to be specified as follows:

  • Name: In this field please enter in TIMPlus.
  • IP Address: This needs to be set to  (the IP Address address of the machine that running TIM Plus is installed on.

...

  • )

Here is an example of a

Referencemacro
Labelnode-names
configuration
 configuration:

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817070/avaya_communications_manager_1.png

Configuring ip-services

You will need to use Issue the change ip-services command to add /ammend ip-or amend IP services. There are three pages that need to be configured, below you will find, by page the fields that need to be configured.In to configure:

On Page 1, you will have the following fields which are required to be populated:

  • Service type: This needs to be set to CDR1.
  • Local Node: This needs to be set  (set this to the node-name of the CLAN board.)
  • Local Port: This  0 (this cannot be changed, it is always set to 0.)
  • Remote Node: This needs to be set to the TIMPlus (the same node-name which was as created in the the node-names section which should be TIMPlus. section above)
  • Remote Port: This is (the TCP port that TIM Plus will be listening on. Generally the 9000 range is normally free so we could recommended you select one from there.

...

  • use to listen for CDR data, e.g.
    Keywordmacro
    Label9000
    )

Here is an example of an ip-services configuration , Page (page 1):

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817070/avaya_communications_manager_2.png

In On Page 2, no configuration changes are needed.

In On Page 3, you will have the following fields which are required to be populated:

  • Reliable Protocol: This needs to be set to n.
  • Packets Resp Timer:

    Please leave this as

     30 (the default

    , which is 30.

    )

  • Sessions Connect Message Cntr: Please leave this as the default, which is 3.
  • SPDU Cntr: Please leave this as the default, which is 3.
  • Connectivity Timer: Please leave this as the default, which is 60.

...