Configuring your SMDR output
Connect to your Avaya Communications Manager using an RS232 or IP terminal client and, after logging in with your administrative credentials, follow the steps below:
Configuring node-names ip
You will need to use the Issue the change node-names command to add a new node. You will have two fields which are required to be populatedTwo fields need to be specified as follows:
- Name: In this field please enter in TIMPlus.
- IP Address: This needs to be set to (the IP Address address of the machine that running TIM Plus is installed on.
...
- )
Here is an example of a
Referencemacro | ||
---|---|---|
|
Screenshotmacro | ||||
---|---|---|---|---|
|
Configuring ip-services
You will need to use Issue the change ip-services command to add /ammend ip-or amend IP services. There are three pages that need to be configured, below you will find, by page the fields that need to be configured.In to configure:
On Page 1, you will have the following fields which are required to be populated:
- Service type: This needs to be set to CDR1.
- Local Node: This needs to be set (set this to the node-name of the CLAN board.)
- Local Port: This 0 (this cannot be changed, it is always set to 0.)
- Remote Node: This needs to be set to the TIMPlus (the same node-name which was as created in the the node-names section which should be TIMPlus. section above)
- Remote Port: This is (the TCP port that TIM Plus will be listening on. Generally the 9000 range is normally free so we could recommended you select one from there.
...
- use to listen for CDR data, e.g.
)Keywordmacro Label 9000
Here is an example of an ip-services configuration , Page (page 1):
Screenshotmacro | ||||
---|---|---|---|---|
|
In On Page 2, no configuration changes are needed.
In On Page 3, you will have the following fields which are required to be populated:
- Reliable Protocol: This needs to be set to n.
Packets Resp Timer:
Please leave this as30 (the default
, which is 30.)
- Sessions Connect Message Cntr: Please leave this as the default, which is 3.
- SPDU Cntr: Please leave this as the default, which is 3.