Configuring your SMDR output
The SMDR output in LG IPLDK is disabled by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.. To enable the output, you need to amend the following programming number codes:
Print Serial Port Selection (PGM 175)
Within this window you need In the Print Serial Port Selection (PGM 175) window, set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG IPLDK to allow connections on TCP port 23 to receive SMDR data.
Below is an example of the Print Serial Port Selection window:
Screenshotmacro | ||||
---|---|---|---|---|
|
SMDR Attributes (PGM 177)
Below is an example of the SMDR Attributes window:
Save Enable: This needs to be disabled
Print Enable: This needs to be enabled
SMDR Record Call Type: This needs to be set to 'All Calls'
Records In Detail: This needs to be enabled
Print Incoming Call: This needs to be enabled
Print Lost Call: This needs to be enabled
SMDR Dial Digit Hidden: Leave this as the default which is '0'
SMDR Currency Unit: Leave this as the default which is blank
SMDR Cost Per Metering Pulse: Leave this as the default which is blank
SMDR Fraction: Leave this as the default which is '0'
SMDR Start Time: Leave this as the default which is '0'
SMDR Hidden Digit: Leave this as the default which is 'Right'
Long Distance Call Digit Counter: Leave this as the default which is '0'
Long Distance Code (Max 2 Digits): Leave this as the default
MSN Print on SMDR: This needs to be disabled
Print Caller Number: This needs to be disabled
Screenshotmacro | ||||
---|---|---|---|---|
|
ISDN Attributes (PGM 200)
Below is an example of the ISDN Attributes window. Please note that the Enable the CLI Print to serial field needs to be enabled., as shown the ISDN Attributes window below:
Screenshotmacro | ||||
---|---|---|---|---|
|
...
If your LG IPLDK has been configured to send SMDR data via a serial connection, you will first need to install the NetPBX software to collect the data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:
...
Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply perform the following settingssteps:
- Click on the tab.
- Select the site configured during the setup wizard Choose the sites you want to configure and click .
Screenshotmacro Border false URL http://docs.call-logger.com:8090/download/attachments/4817111/lg_ipldk_5.png - Within In the Site Properties window, select LG IPLDK from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the button to apply the settings.
...