Configuring your CIL output

CIL access over Ethernet
Info

In addition to CIL access over V.24 ports,

...

all Realitis DX and iSDX systems with

...

firmware revision 6.0

...

and above can send their CIL information by Ethernet. The System/UPI card - ACI - only allows a maximum of three

...

such connections; subsequent connection requests are rejected.

Info

Ethernet port address information is contained in this publication. If the information on how to set-To set up and activate this feature is required, a request must be made via to Product Management at Siemens, Beeston.

Connecting to the CIL server

To gain connection connect to the CIL server on the System/UPI cards, it is necessary for the remote CILE to open TIM Plus opens a TCP /IP connection to the IP address of the active side DX. The connection request must contain the logical port number of the particular service requiredphone system to the CIL port.

The DX IP address of the System/UPI card TCP/IP address is specified by the variable "IPACT" in

Referencemacro
LabelIPACT
 in the permanent database, the . Your local maintenance engineer would normally program this address.

The default listening port is

Referencemacro
Label17257
.

Once a connection is established, the DX will begin sending packets to the connected clientTIM Plus.

HTML
<a id="Configure TIM Plus"></a>

...