Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Stats alarms are alarms that can be added to a selected stats collection point in order to trigger an alert when calls whose properties match certain criteria have happened, such as calls above a particular duration, calls to specific phone numbers, or when user-defined cost thresholds are exceeded. The criteria that must be met to trigger an alarm is user-defined, and email alerts can be sent to one or more recipients.

Call statistics alarms are simply a variation of the standard "alarm" directory object and provide an additional means of keeping a tab on call patterns.

HTML
<a id="Adding a stats alarm"></a>

Adding a stats alarm

To add a stats alarm, click on 

Buttonmacro
LabelLive stats
and select the
Tabmacro
LabelStats alarms
tab. Click on the Add button, as shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_1.png

A new window will open, allowing you to configure the properties of your stats alarm. Each tab displayed in this window is described below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_2.png

General

The

Tabmacro
LabelGeneral
tab allows you to choose a name for the alarm object and select the stats point you want the alarm to be monitoring.

To provide a name for the Stats alarm, enter a name in the Name field, as shown below:

Selection_macro
ValueBusy Channels
SelectionName

To select the stats point you want the alarm to monitor, click on theFind button. A new window will open, allowing you to drill-down to the site or group level in the Directory, where the stats point object you want to use resides. To select the stats point, click on the  icon alongside it, as shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_3.png

Criteria

This section allows you to choose the criteria that calls must match in order to activate the alarm. The criteria available are described below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_4.png

Count

The alarm will be triggered when the call-count of the calls collected in this stats point meets, exceeds, is less than or equal to a predetermined value (e.g. when busy channels equals 10 or busy channels > 10).

Stats_alarms
Value310
Value1Count
Value2greater than

Total duration

The alarm will be triggered when the total duration of the calls collected in this stats point meets, exceeds, is less than or equal to a pre-determined value (e.g. when call duration is greater than 3600 seconds (1 hour) )

Stats_alarms
Value318000
Value1Total duration
Value2greater than

Average duration

The alarm will be triggered when the average duration meets, exceeds, is less than or equal to a pre-determined value (e.g. when average call duration is less than 1 minute).

Stats_alarms
Value360
Value1Average duration
Value2less than

Minimum duration

The alarm will be triggered when the minimum duration meets, exceeds, is less than or equal to a pre-determined value (e.g. when minimum duration equals 20 seconds).

Stats_alarms
Value320
Value1Minimum duration
Value2equals

Maximum duration

The alarm will be triggered when the maximum duration meets, exceeds, is less than or equal to a pre-determined value (e.g. when maximum call duration is greater than 1 hour).

Stats_alarms
Value33600
Value1Maximum duration
Value2greater than

Total response

The alarm will be triggered when the total response time exceeds, equals, is less than or is or equal to a pre-determined value (e.g. total response time exceeds 30 seconds).

Stats_alarms
Value330
Value1Total response
Value2greater than

Average response

The alarm will be triggered when the average response time exceeds, equals, is less than or is equal to a pre-determined value (e.g. average response time exceeds 20 seconds).

Stats_alarms
Value320
Value1Average response
Value2greater than

Minimum response

The alarm will be triggered when the minimum response time exceeds, equals, is less than or is equal to a pre-determined value (e.g. minimum response time equals 2 seconds).

Stats_alarms
Value32
Value1Minimum response
Value2equals

Maximum response

The alarm will be triggered when the maximum response time exceeds, equals, is less than or is equal to a pre-determined value (e.g. maximum response time exceeds 20 seconds)

Stats_alarms
Value320
Value1Maximum response
Value2greater than

Total cost

The alarm will be triggered when the total cost exceeds, equals, is less than or is equal to a pre-determined value (e.g. total cost exceeds £100).

Stats_alarms
Value3100
Value1Total cost
Value2greater

Average cost

The alarm will be triggered when the average cost exceeds, equals, is less than or is equal to a pre-determined value (e.g. average cost exceeds £2.00).

Stats_alarms
Value32
Value1Average cost
Value2greater than

Minimum cost

The alarm will be triggered when the minimum cost exceeds, equals, is less than or is equal to a pre-determined value (e.g. minimum cost equals £1.00).

Stats_alarms
Value31
Value1Minimum cost
Value2equals

Maximum cost

The alarm will be triggered when maximum cost exceeds, equals, is less than or is equal to a pre-determined value (e.g. maximum cost exceeds £10.00).

Stats_alarms
Value310
Value1Maximum cost
Value2greater than

Concurrency

The alarm will be triggered when the call concurrency exceeds, equals, is less than or is equal to a pre-determined value (e.g. total number of simultaneous calls exceeds 20).

Stats_alarms
Value320
Value1Concurrency
Value2greater than

Info

When adding multiple selection criteria, you have the option of triggering an alarm when ALL or ANY of the criteria are met.

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_5.png

Notification

The Notification section allows you to set up for an e-mail to be sent when the criteria of the alarm are met. If you click on the 

Buttonmacro
LabelNotification
tab, the following window will appear:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_6.png

Notification can be sent by e-mail to one or more people. Simply type in the e-mail address, as shown below. If there's more than one, separate each entry by a comma.

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_7.png

You can also add a customised e-mail messages by adding a subject and message as shown in the example below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_8.png

Once you've configured all the settings, press theAddbutton and the Stats alarm will appear as follows:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_9.png

HTML
<a id="Configuring a stats alarm"></a>

Configuring a stats alarm

To configure a Stats alarm, select the entity from the existing list and click on thePropertiesbutton on the top-right corner of the screen, as shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_10.png

Within the new window that opens, you can navigate through theGeneral,CriteriaandNotificationtabs to edit the properties of your stats alarm.

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_11.png

You can use the Adding a Stats alarm page as a reference to edit the properties of your Stats alarm.

HTML
<a id="Deleting a Stats alarm"></a>

Deleting a stats alarm

To delete a stats alarm, select the entity from the list and click on theProperties button on the top-right corner of the screen. Within the new window that opens, click on the

Buttonmacro
LabelDelete
tab to remove the alarm.

Screenshotmacro
Borderfalse
URL/download/attachments/4817592/stats_alarms_12.png