Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

These instructions help you configure your LG IPLDK phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1LG IPLDK.TDT
Supportfiles2LG.TDS
ConnectionActive connection
RequiredTask1Configure the SMDR output
RequiredTask2Configure TIM Enterprise

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

The SMDR output on the LG IPLDK is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:

Print Serial Port Selection (PGM 175)

In this window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Plus over TCP to port 23..

Here is an example of a populated Print Serial Port Selection screen:

Screenshotmacro
Borderfalse
URL/download/attachments/4817111/lg_ipldk_1.png

SMDR Attributes (PGM 177)

Set the SMDR Attributes as shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817111/lg_ipldk_2.png

ISDN Attributes (PGM 200)

Set the ISDN Attributes as shown below, ensuring that the CLI Print to serial field is enabled:

Screenshotmacro
Borderfalse
URL/download/attachments/4817111/lg_ipldk_3.png

HTML
<a id="Configure TIM Enterprise"></a>

Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to collect the SMDR data from your LG iPECS:

  1. Click on the Directory tab.
  2. Choose the PBX object you want to configure and click Properties.
  3. A new window will open. In the General tab, select LG iPECS from the Data format list and tick the Keep a local backup of data box, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/13271191/lg_ipecs_3.png
  4. In the Connection tab, select Establish TCP connection to PBX from the Connection method list.
  5. In the Host field, enter the IP address of your LG iPECS.
  6. In the Port field, enter 23.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field, select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/13271228/lg_ipldk_ip.png