Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Configuring your SMDR output

By default, the SWYX Swyx telephone system writes its CDR data to a MSSQL database. In order for TIM Enterprise to connect to the database and collect the call logging data, you need to create a username and password in the MSSQL database on the SWYX Swyx  server. Contact your system maintainer if you are not familiar with this procedure.

The following information is required for TIM Enterprise to connect to the SWYX Swyx  database:

  • IP address or hostname of the  SWYX Swyx server where the MSSQL database resides.
  • Username and Password of the SWYX Swyx database.

The default credentials for the SWYX  Swyx  database are shown below:

Info

Username: swyxcdrSwyxcdr
Password: swyxcdrSwyxcdr

HTML
<a id="Configure the DSN connection"></a>

...

  1. Open Windows Control Panel and select the Administrative Tools icon

  2. Double-click on the Data Sources (ODBC) icon to open the ODBC Data Source Administrator window

     

    Info

    For a 64 bit system, access the ODBC Data Source Administrator from the following location C:\Windows\SysWOW64\odbcad32.exe

  3. Click on the System DSN tab.
  4. Click on the Add button.
  5. Select SQL Native Client from the driver list and click Finish.
  6. In the Name field, enter SWYXSwyx.
  7. In the Description field, enter TIM Plus link to swyxSwyx.
  8. In the Server field, enter the IP address or hostname of your SWYX Swyx server.
  9. In the Username field, enter the username for your SWYX Swyx database.
  10. In the Password field, enter the password for your SWYX Swyx database.
  11. In the Database drop-down list, select SWYXSwyx.
  12. Click on the Test button to confirm the information you entered is correct and that the connection is successful.
  13. Click on the OK button to close the window.

...

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/16712038/swyx_odbc_2.png
  3. In the Site Properties window, select SWYX Swyx V8 from the PBX model drop-down list.
  4. In the Connection method field, select Connect to a system DSN from the drop-down list.
  5. In the DSN name field, select SWYX Swyx from the drop-down list.
  6. In the Frequency field, enter 5.
  7. In the DB script field, select SWYX Swyx V8 from the drop-down list.