Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

These instructions help you configure your Alcatel OmniPCX Office phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
RequiredTask4Configure TIM Plus
Supportfiles1Alcatel OmniPCX Office.TDT
Supportfiles2Alcatel OmniPCX Office.TDS
Supportfiles3Alcatel OmniPCX Office.DBS
ConnectionFile output
RequiredTask1Configure the SMDR output
RequiredTask2Install Alcatel Office Link Driver
RequiredTask3Set up a DSN connection

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Info

Before enabling the SMDR output, you will need to speak with your phone maintainer to buy the required licenses for your Alcatel phone system.

Follow the instructions below to configure the SMDR output for your Alcatel OmniPCX Office phone system:

Alcatel-Lucent OmniPCX Office Communication Server supports two types of call metering:

  • V24 metering supports V24 printing for all call metering tickets
  • IP metering supports IP printing for call metering tickets originating from a 3rd party application (Business or Hotel) via an IP connection

The type of metering must be specified when the Office Link driver is installed. The driver can be set to one of two modes: hotel or metering. You can use the OMC Counting function to specify the type of call metering for hardcopy printouts.

To set printing options for call metering tickets, follow the steps below:

  1. Open the Counting function window in the OMC console and select the Accounting Printout tab.
  2. Select the metering type from the drop-down list:  Ext. Accounting Activation IP or Ext. Accounting Activation V24.
  3. Click OK to save the settings.

The table below presents a summary of the data output from an Alcatel:

Screenshotmacro
Borderfalse
URL/download/attachments/4817041/alcatel_pbxs.png

HTML
<a id="Install Alcatel Office Link Driver"></a>

Installing the Alcatel Office Link Driver

If your Alcatel OmniPCX Office has been configured to send SMDR data via IP, you first need to install the Alcatel Office Link Driver to configure the output.

For information on how to install the Alcatel Office Link Driver, please refer to the Alcatel OmniPCX Office manual or speak to your system maintainer.

HTML
<a id="Set up a DSN connection"></a>

Setting up a DSN connection for TIM Plus

To enable TIM Plus to work with the Alcatel Office Link Driver, you need to setup a DSN connection. Follow the instructions below to perform this operation within Microsoft Windows:

  1. Open 
    Referencemacro
    LabelWindows Control Panel
    .
  2. Double click on the Administrative tools icon.
  3. Double click on theData Sources (ODBC) icon to open the ODBC Data Source Administrator window.

    Info

    For a 64 bit system, access the ODBC Data Source Administrator from the following location C:\Windows\SysWOW64\odbcad32.exe

  4. Click on the System DSN tab.
  5. Click on the Add button.
  6. Select Native from the list of drivers and click Finish.
  7. In the Name field enter: TIM Plus - Alcatel OHL.
  8. In the Database name field enter: Native.
  9. Click on the OK button, then close the window.

An example of an ODBC setup is shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817043/alcatel_omnipcx_office_1.png

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once the DSN connection has been set up, log in to TIM Plus and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817043/alcatel_omnipcx_office_2.png
  3. In the Site Properties window, select Alcatel OmniPCX Office from the PBX model drop-down list.
  4. In the Connection method field, select Connect to a system DSN from the drop-down list.
  5. In the DSN name field, select TIM Plus - Alcatel OHL from the drop-down list.
  6. In the Frequency field, enter to check for data every five seconds.
  7. In the DB script field, select Alcatel OmniPCX Office OHL from the drop-down list.
  8. Click on the Save button to apply the settings.