Code Block |
---|
callinfo_output_set -output 0 -lim 1 -type file -subtype general -local -dbname /var/opt/eri_sn/call_logging/log0 -format ": {stoptime md110date L 4 4}{stoptime md110time L 4 4}{stoptime second 0R 2 2} {duration md110duration L 5 5}; [taxpulses != 0]: {taxpulses R 4 4}; [taxpulses == 0]: ; {conditionCodeUserDefined L 3 3} {accesscode1 R 5 5}{accesscode2 R 5 5}; [conditionCodePos == 17]: {chargedNumber R 20 20}; [conditionCodePos != 17]: {dialednumber R 20 20}; {callingnumber L 20 20} {accountcode L 15 15} {cilcode L 6 6} {queueTimeCounter 0R 3 3} {ringTimeCounter 0R 3 3} {ogTrnkId R 10 10} {incTrnkId R 10 10} {connectedNumber R 16 16}{return}{newline};" -eol NL -record call -localtime |
Code Block |
---|
callinfo_output_set -output 1 -lim 1 -type tcp -subtype general -server 192.168.0.1 -port 9000 -format ": {stoptime md110date L 4 4}{stoptime md110time L 4 4}{stoptime second 0R 2 2} {duration md110duration L 5 5}; [taxpulses != 0]: {taxpulses R 4 4}; [taxpulses == 0]: ; {conditionCodeUserDefined L 3 3} {accesscode1 R 5 5}{accesscode2 R 5 5}; [conditionCodePos == 17]: {chargedNumber R 20 20}; [conditionCodePos != 17]: {dialednumber R 20 20}; {callingnumber L 20 20} {accountcode L 15 15} {cilcode L 6 6} {queueTimeCounter 0R 3 3} {ringTimeCounter 0R 3 3} {ogTrnkId R 10 10} {incTrnkId R 10 10} {connectedNumber R 16 16}{return}{newline};" -eol NL -record call -localtime |
Info |
---|
The server IP address specified above will be the IP address of the TIM Plus machine. The port number can be set to any free TCP port, but we would recommend one in the 9000 range. |
...