These instructions help you configure your Avaya Aura Communications Manager phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1Avaya Communications Manager.TDT
Supportfiles2Avaya Communications Manager.TDS
Requiredtask1Configure the SMDR output
Requiredtask2Configure TIM Plus
ConnectionListening connection
RequiredTask1Configure the SMDR output
RequiredTask2Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Connect to your Avaya AursCommunications Manager using an RS232 or IP terminal client and, after logging in with your administrative credentials, follow the steps below:

Configuring node-names ip

Issue the change node-names command to add a new node. Two fields need to be specified as follows:

  • Name: TIMPlus.
  • IP Address: (the IP address of the machine running TIM Plus)

Here is an example of a

Referencemacro
Labelnode-names
 configuration:

Screenshotmacro
Borderfalse
URL/download/attachments/4817070/avaya_communications_manager_1.png

Configuring ip-services

Issue the change ip-services command to add or amend IP services. There are three pages to configure:

On Page 1, the following fields are required:

  • Service type: CDR1
  • Local Node: (set this to the node-name of the CLAN board)
  • Local Port: 0 (this cannot be changed)
  • Remote Node: TIMPlus (the same node-name as created in the node-names section above)
  • Remote Port: (the TCP port that TIM Plus will use to listen for CDR data, e.g.
    Keywordmacro
    Label9000
    )

Here is an example of an ip-services configuration (page 1):

Screenshotmacro
Borderfalse
URL/download/attachments/4817070/avaya_communications_manager_2.png

On Page 2 no configuration changes are needed.

On Page 3 the following fields are required:

  • Reliable Protocol: n
  • Packets Resp Timer:  30 (default value)
  • Sessions Connect Message Cntr: (default value)
  • SPDU Cntr: (default value)
  • Connectivity Timer: 60 (default value)

Here is an example of an ip-services configuration (page 3):

Screenshotmacro
Borderfalse
URL/download/attachments/4817070/avaya_communications_manager_3.png

Configuring system-parameters cdr

Use the change system-parameters cdr command to amend the CDR format. The following screenshots describe how the settings should appear on your system:

Page 1

Screenshotmacro
Borderfalse
URL/download/attachments/4817070/avaya_communications_manager_4.png

Page 2

Screenshotmacro
Borderfalse
URL/download/attachments/4817070/avaya_communications_manager_5.png

Configuring trunk-group

To ensure that response times for incoming calls are included in your CDR data, the CDR field for each trunk group must be set to r.  This must be applied to all trunk groups using the following command:

 change trunk-group X  (where X is the trunk group number)

An example trunk-groups configuration screen is shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817070/avaya_communications_manager_6.png

Configuring intra-switch-cdr

To have internal calls included in your CDRs, ensure that the intra-switch-cdr table is populated with the extension numbers you are interested in.  To modify the table, issue the following command:

 change intra-switch-cdr

Here is an example of an intra-switch-cdr configuration table:

Screenshotmacro
Borderfalse
URL/download/attachments/4817070/avaya_communications_manager_7.png

Configuring multiple Avaya Aura Communications Manager systems

If you have more than one Avaya Aura Communications Manager, the configuration of your CDR depends on which of the following scenarios you have implemented:

  • LSPs (Local Survivable Processors)
    If your Avaya Aura Communications Manager systems are connected and the remote sites are LSPs then you need only configure the Master/Primary Avaya Communications Manager. When TIM Plus receives the CDR information, it will include CDRs from all of the remote LSPs.
  • Not linked
    If you have multiple Avaya Aura Communications Manager systems where LSPs aren't in use, you need to configure each Avaya Communications Manager separately. You must ensure that each Avaya Communications Manager has its own unique Remote Port (IP-services) setup.
HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Follow the steps below to configure TIM Plus to listen for SMDR data from your Avaya Aura Communications Manager:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817070/avaya_communications_manager_8.png
  3. In the Site Properties window, select Avaya Communications Manager from the PBX model drop-down list.
  4. In the Connection method field, select Listen for connections from PBX from the drop-down list.
  5. Leave the Host field blank.
  6. In the Port field, enter the Remote Port (ip-services) that you configured above.
  7. Click on the Options tab and tick the box Timestamp received data.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817070/avaya_communications_manager_9.png
  8. Click on the Save button to apply the settings.