These instructions help you configure your NEC Aspire phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR output
Follow the steps below to configure the SMDR output on your NEC Aspire:
- Log in to your PC Pro/Web Pro software.
To configure SMDR output by serial port, apply the following settings for each system adapter:
Adapter Programming code Value Description NTCPU - Serial 10-21-02 1 NTCPU Hardware Setup - Baud Rate for COM Port. Choose the baud rate from the three available options: 0 = 4800, 1 = 9600, and 2 = 38400 35-01-01 1 SMDR Options - Output Port Type CTA/CTU - Serial 15-02-19 1 Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module 15-02-20 1 Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. Choose from the three available options: 0 = 4800, 1 = 9600, and 2 = 38400 35-01-01 4 SMDR Options - Output Port Type 35-01-02 Extension number that the CTA/CTU adaptor is attached to. SMDR Options - Output Destination Number Apply the following settings in the programming sections below:
Programming code Value Description 14-01-06 1 Basic Trunk Data Setup - SMDR Print. 15-01-03 1 Basic Extension Data Setup - SMDR Print. 35-01-03 0 SMDR Options - Header Language. 35-01-04 0 SMDR Options - Omit (Mask) Digits. 35-01-05 0 SMDR Options - Minimum Number of SMDR Digits. 35-01-06 0 SMDR Options - Minimum Call Duration. 35-01-07 0 SMDR Options - Minimum Ringing Time. 35-01-08 Default SMDR Options - SMDR Format. 35-02-01 0 SMDR Output Options - Toll Restricted Call. 35-02-02 1 SMDR Output Options - PBX Calls. 35-02-03 1 SMDR Output Options - Display Trunk Name or Numbers. 35-02-04 0 SMDR Output Options - Daily Summary. 35-02-05 0 SMDR Output Options - Weekly Summary. 35-02-06 0 SMDR Output Options - Monthly Summary. 35-02-08 1 SMDR Output Options - Incoming calls. 35-02-09 0 SMDR Output Options - Print Name or Numbers. 35-02-10 0 SMDR Output Options - All Lines Busy (ALB) Output. 35-02-12 0 SMDR Output Options - DID Table Name Output. 35-02-13 1 SMDR Output Options - CLI Output when DID to Trunk. 35-02-14 1 SMDR Output Options - Date. 35-02-15 1 SMDR Output Options - CLI/DID Number Switching. 35-02-16 1 SMDR Output Options - Print Trunk Name or Received Dialled Number. 35-02-17 0 SMDR Output Options - Print Account Code or Caller ID Name. 35-02-18 Default SMDR Output Options - Caller ID Name Output Method. 80-05-01 1 Date Format for SMDR and System Reports.
HTML |
---|
<a id="Install NetPBX"></a> |
Installing NetPBX
To capture SMDR data from your NEC Aspire using a serial connection, you first need to install the netpbx software to collect the data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Once NetPBX is configured and collecting data, log in to TIM Plus and perfrom the steps below:
- Click on the tab.
- Choose the site you want to configure and click .
Screenshotmacro Border false URL /download/attachments/4817104/nec_aspire_2.png - In the Site Properties window, select NEC Aspire from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the button to apply the settings.