These instructions help you configure your LG IPLDK phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1LG IPLDK.TDT
Supportfiles2LG.TDS
ConnectionActive connection
RequiredTask1Configure the SMDR output
RequiredTask2Configure TIM Enterprise

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

The SMDR output on the LG IPLDK is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:

Print Serial Port Selection (PGM 175)

In this window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Enterprise over TCP to port 23.

Screenshotmacro
Borderfalse
URL/download/attachments/4817111/lg_ipldk_1.png

SMDR Attributes (PGM 177)

Set the SMDR Attributes as shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817111/lg_ipldk_2.png

ISDN Attributes (PGM 200)

Set the ISDN Attributes as shown below, ensuring that the CLI Print to serial field is enabled:

Screenshotmacro
Borderfalse
URL/download/attachments/4817111/lg_ipldk_3.png

HTML
<a id="Configure TIM Enterprise"></a>

Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to collect the SMDR data from your LG IPLDK:

  1. Click on the Directory tab.
  2. Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
  3. A new window will open, displaying the general properties of your PBX object. Select LG IPLDK from the Data format list and tick the 
    Keywordmacro
    LabelKeep a local backup of data
    box, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/13271191/lg_ipecs_3.png
  4. Click on the Connection tab and select Establish TCP connection to PBX from the Connection method list.
  5. In the Host field, enter the IP address of your LG IPLDK.
  6. In the Port field, enter 23.
  7. Leave the Username and Password fields blank.
  8. In the IP script field, select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.
    Screenshotmacro