Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

These instructions help you configure your Alcatel PmniPCX OmniPCX Enterprise phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1Alcatel OmniPCX Enterprise.TDT
Supportfiles2Alcatel OmniPCX Enterprise.TDS
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Info

 Before enabling the SMDR output, you will need to speak with your phone maintainer to buy the required licenses for your Alcatel phone system.

Follow the instructions below to configure the SMDR output via a serial connection. These instructions are taken from the Alcatel OmniPCX Enterprise manual:

Using Telnet, connect to the IP address of your Alcatel OmniPCX Enterprise and follow the steps below:

  1. Applications (Enter)
  2. Accounting (Enter)
  3. Review/Modify (Enter)
  4. All Instance (F1)
  5. Realtime ticket Output: Set this to ethernet. Note that if you don't have an appropriate license, you may only select V24 (serial) here.
  6. Save changes and exit.

Below is an example of the data output from an Alcatel OmniPCX Enterprise:

Screenshotmacro
Borderfalse
URL/download/attachments/4817041/alcatel_pbxs.png

HTML
<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817042/alcatel_omnipcx_enterprise_2.png
  3. In the Site Properties window, select Alcatel OmniPCX Enterprise from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.