These instructions help you configure your Siemens OpenOffice phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary |
---|
RequiredTask4 | Configure TIM Plus |
---|
Supportfiles1 | Siemens OpenOffice.TDT |
---|
Supportfiles2 | Siemens OpenOffice.TDS |
---|
Supportfiles3 | Siemens OpenOffice.DBS |
---|
Connection | DSN connection |
---|
RequiredTask1 | Configure the SMDR output |
---|
RequiredTask2 | Set up a DSN connection |
---|
RequiredTask3 | Configure TIM Plusthe interface file |
---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR output
By default, the SMDR output of a Siemens OpenOffice is not enabled. Contact Contact your system maintainer to enable it for incoming, outgoing and internal calls.
HTML |
---|
<a id="Set up a DSN connection"></a> |
Setting up a DSN connection
To enable TIM Plus to work with the Siemens OpenOffice, you first need to set up a DSN connection, by following the steps below:
- Open Windows Control Panel.
- Double-click on the Administrative tools icon.
Double-click on the Data Sources (ODBC) icon to open the ODBC Data Source Administrator window
Info |
---|
For a 64 bit system, access the ODBC Data Source Administrator from the following location C:\Windows\SysWOW64\odbcad32.exe |
- Click on the System DSN tab.
- Click on the Add button.
- Select Native from the driver list and click Finish.
- In the Data source name field enter Siemens OpenOffice.
- Click on the OK button to save the changes.
An example of an ODBC entry is shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817029/siemens_openoffice_1.png |
---|
|
HTML |
---|
<a id="Configure the interface file"></a> |
Configuring the interface file
Follow the steps below to configure the interface file to establish an HTTPS connection with your Siemens OpenOffice:
- Open the
Referencemacro |
---|
Label | Siemens OpenOffice.TDT |
---|
|
file, located by default in Referencemacro |
---|
Label | C:\Program Files (x86)\Tri-Line\TIM Plus\config |
---|
|
. - Edit the file to point to the IP address of your Siemens OpenOffice and enter the relevant username and password, as shown below:
Screenshotmacro |
---|
URL | /download/attachments/4817029/siemens_openoffice_4.png |
---|
|
- Remove the apostrophe (') in front of the amended fields to enable them. An example of a configured interface file is shown below:
Screenshotmacro |
---|
URL | /download/attachments/4817029/siemens_openoffice_5.png |
---|
|
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Once the DSN connection has been set up, log in to TIM Plus and follow the steps below:
- Click on the Directory tab.
- Choose the site you want to configure and click Properties.
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817029/siemens_openoffice_2.png |
---|
|
- In the Site Properties window, select Siemens OpenOffice from the PBX model drop-down list.
- In the Connection method field, select Connect to a system DSN from the drop-down list.
- In the DSN name field, select Siemens OpenOffice from the drop-down list.
- In the Frequency field, enter 5.
- In the DB script field, select Siemens
OpenOffice- from the drop-down list.
- Click on the Save button to apply the settings.