These instructions help you configure your Nortel/Avaya BCM 4(v4.x0+) phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary |
---|
Supportfiles1 | Avaya BCM.TDT |
---|
Supportfiles2 | Avaya BCM.TDS |
---|
Requiredtask1 | Configuring the SMDR output |
---|
Requiredtask3 | Create a CDR User |
---|
Requiredtask2 | Configuring TIM Plus |
---|
Connection | Active connection |
---|
RequiredTask1 | Configure the SMDR output |
---|
RequiredTask2 | Configure a CDR user |
---|
RequiredTask3 | Configure TIM Plus |
---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR
...
output
Follow the steps below to configure your Nortel/Avaya BCM v4.x+ to output SMDR data to TIM Plus:
- Login Log in to the BCM Element Manager.
- On the Task Navigation Panel, click the Configuration tab.
- Click on Telephony.
Click on Call Detail Recording.
- On the right-hand side the Call Detail Recording window will appear.
In the Call Detail Recording window panel that appears, configure the options as below:
SMDR field | Value |
---|
Format | Norstar |
Report Type | All |
Language | English |
Date Format | MM/DD/YY |
Header Format | Line/Station |
Filter Type | All |
Feature Code F9 | Leave as default |
Minimum Call Duration | Leave as default |
Hospitality Records | Leave as default |
Include DNIS Info | Enable |
Include CLID with call type | Enable |
Include Long CLID | Leave as default |
Use answer supervision | Leave as default |
Display connection character | Leave as default |
Suppress digits after connect | Leave as default |
Maximum digits after connect | Leave as default |
HTML |
---|
<a id="infoConfigure a CDR user"></a> |
CDR User
To enable TIM Plus to connect to your your Avaya BCM v4.x+, you will need to create a
in your phone system. This can be configured within your Business Communications Manager Unified Manager appliction, under under the
options. option in the BCM Unified Manager configuration utility. HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Below you will find steps on how Follow the steps below to configure TIM Plus to collect the SMDR data from your Nortel/Avaya BCM:
- Log on in to TIM Plus and click on the Directory tab.
- Click on Choose the site configured during the setup wizard you want to configure and click Properties.
Screenshotmacro |
---|
Border | false |
---|
URL | http://docs.call-logger.com:8090/download/attachments/48170684817069/avaya_bcm_12.png |
---|
|
- Within In the Site Properties window, select Avaya BCM from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP Address address of your Avaya BCM.
- In the Port field, enter in 4000.
- In the Username field, enter in CDR User.the username of the CDR user you configured in the BCM Unified Manager utility (above)
- In the Password field, enter in CDR User againthe password for the CDR user.
- In the Connection script field, select Avaya BCM v3v4 from the drop-down list.
- Click on the Save button to apply the settings.
HTML |
---|
<hr/>
<p>These instructions should assist in configuring your Avaya BCM to
work with TIM Plus. If you are not familiar with PBX
configuration, please contact your system maintainer.</p>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>Connection information</th>
<th class="confluenceTh">Description</th>
</tr>
<tr>
<td class="confluenceTd"><b>Connection type</b></td>
<td class="confluenceTd"><b>IP: </b>
The Avaya BCM v4.x+ CDR information is sent via TCP/IP. The actual installation of TIM Plus can be anywhere on the network that the PBX is connected to.
</td>
</tr>
<tr>
<td class="confluenceTd"><b>IP method</b></td>
<td class="confluenceTd">TIM Plus will connect to the IP address of your Avaya BCM v4.x+.
</td>
</tr>
</tbody>
</table>
<h2>Configuring your SMDR</h2>
<p>Below you will find instructions on how to configure your Avaya BCM v4.x+ to output SMDR to TIM Plus:</p>
<ol>
<li>Login to the BCM Element Manager.</li>
<li>On the <span class="reference">Task Navigation Panel</span>, click the <span class="button no_margin">Configuration</span> tab.</li>
<li>Click on <span class="button no_margin">Telephony</span>.</li>
<li>Click on <span class="button no_margin">Call Detail Recording</span>.</li>
<li>On the right-hand side the <span class="reference">Call Detail Recording</span> window will appear.</li>
<li>In the <span class="reference">Call Detail Recording</span> window, configure the options as below:</li>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=200>SMDR field</th>
<th class="confluenceTh">Value</th>
</tr>
<tr>
<td class="confluenceTd"><b>Format</b></td>
<td class="confluenceTd"><span class="keyword">Norstar</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Report Type</b></td>
<td class="confluenceTd"><span class="keyword">All</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Language</b></td>
<td class="confluenceTd"><span class="keyword">English</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Date Format</b></td>
<td class="confluenceTd"><span class="keyword">MM/DD/YY</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Header Format</b></td>
<td class="confluenceTd"><span class="keyword">Line/Station</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Filter Type</b></td>
<td class="confluenceTd"><span class="keyword">All</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Feature Code F9</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Minimum Call Duration</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Hospitality Records</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Include DNIS Info</b></td>
<td class="confluenceTd"><span class="keyword">Enable</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Include CLID with call type</b></td>
<td class="confluenceTd"><span class="keyword">Enable</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Include Long CLID</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Use answer supervision</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Display connection character</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Suppress digits after connect</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Maximum digits after connect</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
</tbody>
</table>
</ol>
<h4>CDR User</h4>
<p>For TIM Plus to connect to the Avaya BCM v4.x+ you will need to
create a <span class="reference">CDR User</span> on it. This can be done in the BCM Elements Manager
application, under the <span class="button">System</span> options.</p>
<h2>Configuring TIM Plus</h2>
<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Avaya BCM 4.0:</p>
<ol>
<li>Browse to TIM Plus as normal and login with your credentials.</li>
<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span> or create a new site and click <span class="button no_margin">Properties</span>.</li>
<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/avaya_bcm_2.png" alt="Avaya BCM 4.0" />
<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">Avaya BCM</span> from the <span class="reference">PBX model</span> drop-down list.</li>
<li>In the <span class="reference">Connection method</span> field select <span class="keyword">Actively connect to PBX</span> from the drop-down list.</li>
<li>In the <span class="reference">Host</span> field enter the IP Address of your Avaya BCM.</li>
<li>In the <span class="reference">Port</span> field enter in <span class="keyword">4000</span>.</li>
<li>In the <span class="reference">Username</span> field enter in <span class="keyword">CDR User</span>.</li>
<li>In the <span class="reference">Password</span> field enter in <span class="keyword">CDR User</span> again.</li>
<li>In the <span class="reference">Connection script</span> field select <span class="keyword">Avaya BCM v4</span> from the drop-down list.</li>
<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol> |