These instructions help you configure your Nortel/Avaya BCM 4(v4.x0+) phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
...
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR
...
output
Follow the steps below to configure your Nortel/Avaya BCM v4.x+ to output SMDR data to TIM Plus:
- Login Log in to the BCM Element Manager.
- On the Task Navigation Panel, click the tab.
- Click on .
Click on .
On the right-hand side the Call Detail Recording window will appear.
In the Call Detail Recording window panel that appears, configure the options as below:
SMDR field Value Format Norstar Report Type All Language English Date Format MM/DD/YY Header Format Line/Station Filter Type All Feature Code F9 Leave as default Minimum Call Duration Leave as default Hospitality Records Leave as default Include DNIS Info Enable Include CLID with call type Enable Include Long CLID Leave as default Use answer supervision Leave as default Display connection character Leave as default Suppress digits after connect Leave as default Maximum digits after connect Leave as default
HTML |
---|
<a id="Configure a CDR user"></a> |
CDR User
To enable TIM Plus to connect to your your Avaya BCM v4.x+, you will need to create a
Referencemacro | ||
---|---|---|
|
Buttonmacro | ||
---|---|---|
|
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Below you will find steps on how Follow the steps below to configure TIM Plus to collect the SMDR data from your Nortel/Avaya BCM:
- Log on in to TIM Plus and click on the tab.
- Click on Choose the site configured during the setup wizard you want to configure and click .
Screenshotmacro Border false URL http://docs.call-logger.com:8090/download/attachments/48170684817069/avaya_bcm_12.png - Within In the Site Properties window, select Avaya BCM from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host fiel field, d enter the IP Address address of your Avaya BCM.
- In the Port field, enter in 4000.
- In the Username field, enter in CDR User.the username of the CDR user you configured in the BCM Unified Manager utility (above)
- In the Password field, enter in CDR User againthe password for the CDR user.
- In the Connection script field, select Avaya BCM v3v4 from the drop-down list.
- Click on the button to apply the settings.