Pbxsummary |
---|
RequiredTask4 | Configure TIM Plus |
---|
Supportfiles1 | Unify OpenScape Business.TDT |
---|
Supportfiles2 | Unify OpenScape Business.TDS |
---|
Supportfiles3 | Unify OpenScape Business.DBS |
---|
Connection | DSN connection |
---|
RequiredTask1 | Configure the SMDR output |
---|
RequiredTask2 | Configure the Set up a DSN connection |
---|
RequiredTask3 | Configure the interface file |
---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring the SMDR output
Follow the instructions below to configure the SMDR output in your phone system. These instructions are taken from the Unify OpenScape Busines Business manual:.
- Log on to OpenScape Business Assistant and click on -> -> , as shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/1504053715040530/unify_openscape_business_1.png |
---|
|
- Click to start the
Referencemacro |
---|
Label | Call Detail Recording |
---|
|
wizard. - In the new window that opens, tick the
Keywordmacro |
---|
Label | Activate Call Charge Recording |
---|
|
to enable the CDR output, as shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/1504053715040530/unify_openscape_business_2.png |
---|
|
HTML |
---|
<a id="SettingSet up a DSN connection"></a> |
Setting up a DSN connection
The default SMDR output option in the Unify OpenScape Business phone system is
. To enable TIM Plus to work with Unify OpenScape Business, you first need to set up a DSN connection, by following the steps below:
...
HTML |
---|
<a id="Configure the interface file"></a> |
Configuring the interface file
Follow the steps below to configure the interface file to establish an HTTPS connection with your Siemens Unify OpenScape Business:
- Open the Siemens Unify OpenScape Business.TDT file, located by default in C:\Program Files (x86)\Tri-Line\TIM Plus\config.
- Edit the file to point to the IP address of your Siemens your Unify OpenScape Business and enter the relevant username and password, as shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/1504053715040530/unify_openscape_business_tdt_1.png |
---|
|
- Remove the apostrophe (') in front of the amended fields to enable them. An example of a configured interface file is shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/1504053715040530/unify_openscape_business_tdt_2.png |
---|
|
HTML |
---|
<a id="ConfiguringConfigure TIM Plus"></a> |
Configuring TIM Plus
Once the DSN connection has been set up, log in to TIM Plus and follow the steps below:
- Click on the Directory tab.
- Choose the site you want to configure and click Properties.
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/15040537/unify_openscape_business_tim_DSN.png |
---|
|
- In the Site Properties window, select Siemens Unify OpenScape Business from the PBX model drop-down list.
- In the Connection method field, select Connect to a system DSN from the drop-down list.
- In the DSN name field, select Siemens Unify OpenScape Business from the drop-down list.
- In the Frequency field, enter 5.
- In the DB script field, select Siemens Unify OpenScape Business from the drop-down list.
- Click on the Save button to apply the settings.