These instructions help you configure your LG iPECS phone system to work with TIM PlusEnterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary |
---|
Supportfiles1 | LG iPECS.TDT |
---|
Supportfiles2 | LG.TDS |
---|
Connection | Serial connection |
---|
RequiredTask1 | Configure the SMDR output |
---|
RequiredTask2 | Install NetPBX |
---|
RequiredTask3 | Configure TIM PlusEnterprise |
---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configure the SMDR output
The SMDR output in LG iPECS is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:
SMDR Attributes (PGM 177)
Field | Description |
---|
Save Enable | Leave this as the default, which is unticked |
Print Enable | This needs to be enabled by clicking on the check box |
SMDR Record Call Type | This needs to be set to 'All Calls', you will need to select this from the drop-down list |
Records In Detail | This needs to be enabled by clicking on the check box |
Print Incoming Call | This needs to be enabled by clicking on the check box |
Print Lost Call | This needs to be enabled by clicking on the check box |
SMDR Dial Digit Hidden | Leave this as the default which is '0' |
SMDR Currency Unit | Leave this as the default which is blank |
SMDR Cost Per Metering Pulse | Leave this as the default which is blank |
SMDR Fraction | Leave this as the default which is '0' |
SMDR Start Time | Leave this as the default which is '0' |
SMDR Hidden Digit | Leave this as the default which is 'Right' |
Long Distance Call Digit Counter | Leave this as the default which is '0' |
Long Distance Code (Max 2 Digits) | Leave this as the default |
MSN Print on SMDR | Leave this is the default which is unticked |
Print Caller Number | This needs to be enabled by clicking on the check box
|
Here is an example of a populated SMDR Attributes screen:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817110/lg_ipecs_1.png |
---|
|
Printer Port Selection (PGM 175)
In the Printer Port Selection (PGM 175) window, set Info/On-line SMDR to COM1/COM2 to send call logging data by serial port.
ISDN Attributes (PGM 200)
To enable CLI information in the call records produced by your LG iPECS, you need to set the CLI Print To Serial to ON, as shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817110/lg_ipecs_2.png |
---|
|
HTML |
---|
<a id="Install NetPBX"></a> |
Installing NetPBX
If your LG iPECS has been configured to send SMDR data via a serial connection, you first need to install the netpbx software to collect data from the serial port and send it to TIM Enterprise. For setup instructions, click on the link below:
Install and configure NetPBX
HTML |
---|
<a id="Configure TIM Enterprise"></a> |
Configuring TIM Enterprise
Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:
- Click on the Directory tab.
- Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
- A new window will open, displaying the general properties of your PBX object. select LG iPECS from the Data format list and tick the
Keywordmacro |
---|
Label | Keep a local backup of data |
---|
|
box, as shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/13271191/lg_ipecs_3.png |
---|
|
- Click on the Connection tab and select No connection required from the Connection method list.
- Click on the Save button to apply the settings.
Screenshotmacro |
---|
Border | false |
---|