Follow the steps below to enable the SMDR output in your telephone system:
- Log in to the Siemens OpenOffice web portal.
- Click on and then select .
- Under the menu options, select
Keywordmacro |
---|
Label | Call Charges - Output Format |
---|
|
and tick the SMDR options shown below:
Screenshotmacro |
---|
Border | false |
---|
Shadow | false |
---|
URL | /download/attachments/17400158/siemens_openoffice_IP_2.png |
---|
|
- Under options, select from the drop-down list, as the output format.
- In the field, enter the IP address of the PC running TIM Enterprise and the port number that you want your SMDR data to be sent to. You can use any free TCP port, but we would recommend on e in the 9000 range.
- Click on the tab to save the changes.
HTML |
---|
<a id="ConfiguringConfigure TIM Enterprise"></a> |
Configure TIM Enterprise
Follow the steps below to configure TIM Enterprise to collect the SMDR data from your telephone system:
- Click on the Directory tab.
- Choose Locate the site PBX object you want to configure and click Properties.
in the Directory, right-click on it and select Properties. - A new window will open, displaying the general properties of your PBX object. Select Siemens OpenOffice from the Data format list and tick the
Keywordmacro |
---|
Label | Keep a local backup of data |
---|
|
box, as shown below:
http: /docs.tri-line.com/ 1740015817400156/siemens_openoffice_IP_ |
|
1- In the Site Properties window, select Siemens OpenOffice from the PBX model drop-down list.
- In the Connection method field, select Actively connect Click on the Connection tab and select Establish TCP connection to PBX from the drop-down Connection method list.
- In the Host field, enter the IP address of your Siemens OpenOffice telephone system.
- In the Port field, enter the port number you have configured in the phone telephone system.
- Leave the Username and Password fields blank.
- In the
Connection - IP script field, select Siemens OpenOffice from the drop-down list.
- Click on the Save button to apply the settings.