...
Configuring your SMDR output
Below you will find details on how Follow the steps below to configure the SMDR output on the your NEC Aspire. The programming will need to be done via PC Pro/Web Pro:
- Log in to your PC Pro/Web Pro software.
As the NEC Aspire has multiple ways of sending SMDR data, below are the configuration settings based on each adaptor:
AdaptorTo configure SMDR output by serial port, apply the following settings for each system adapter:
Adapter Programming code Value Description NTCPU - IP 10-12-01 IP address that TIM Plus will connect to. NTUCPU Network Setup - IP Address. 10-20-01 TCP port that TIM Plus will connect to. We recommend using 9000 and increment it for each NEC Aspire you configure. LAN Setup for External Equipment. NTCPU - Serial 10-21-02 1 NTCPU Hardware Setup - Baud Rate for Com COM Port. In this screen you need to configure Choose the baud rate for from the com port, you have three available options, : 0 (= 4800), 1 (= 9600) , and 2 (= 38400). 35-01-01 1 SMDR Options - Output Port Type. CTA/CTU - Serial 15-02-19 1 Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module. 15-02-20 1 Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(19200).Choose from the three available options: 0 = 4800, 1 = 9600, and 2 = 38400 35-01-01 4 SMDR Options - Output Port Type. 35-01-02 Extension number that the CTA/CTU adaptor is attached to. SMDR Options - Output Destination Number. You also need to configure Apply the following settings in the programming codessections below:
Programming code Value Description 14-01-06 1 Basic Trunk Data Setup - SMDR Print. 15-01-03 1 Basic Extension Data Setup - SMDR Print. 35-01-03 0 SMDR Options - Header Language. 35-01-04 0 SMDR Options - Omit (Mask) Digits. 35-01-05 0 SMDR Options - Minimum Number of SMDR Digits. 35-01-06 0 SMDR Options - Minimum Call Duration. 35-01-07 0 SMDR Options - Minimum Ringing Time. 35-01-08 Default SMDR Options - SMDR Format. 35-02-01 0 SMDR Output Options - Toll Restricted Call. 35-02-02 1 SMDR Output Options - PBX Calls. 35-02-03 1 SMDR Output Options - Display Trunk Name or Numbers. 35-02-04 0 SMDR Output Options - Daily Summary. 35-02-05 0 SMDR Output Options - Weekly Summary. 35-02-06 0 SMDR Output Options - Monthly Summary. 35-02-08 1 SMDR Output Options - Incoming calls. 35-02-09 0 SMDR Output Options - Print Name or Numbers. 35-02-10 0 SMDR Output Options - All Lines Busy (ALB) Output. 35-02-12 0 SMDR Output Options - DID Table Name Output. 35-02-13 1 SMDR Output Options - CLI Output when DID to Trunk. 35-02-14 1 SMDR Output Options - Date. 35-02-15 1 SMDR Output Options - CLI/DID Number Switching. 35-02-16 1 SMDR Output Options - Print Trunk Name or Received Dialled Number. 35-02-17 0 SMDR Output Options - Print Account Code or Caller ID Name. 35-02-18 Default SMDR Output Options - Caller ID Name Output Method. 80-05-01 1 Date Format for SMDR and System Reports.
HTML |
---|
<a id="Install NetPBX"></a> |
Installing NetPBX
If To capture SMDR data from your NEC Aspire has been configured to send SMDR data via using a serial connection, you will first need to install the NetPBX netpbx software to collect the data from the serial port and send it to Tim TIM Plus. For setup instructions, click on the link below:
HTML |
---|
<a id="Configure TIM Plus"></a> |
...
Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply perfrom the following settingssteps below:
- Click on the tab.
- Click on Choose the site configured during the setup wizard you want to configure and click .
Screenshotmacro Border false URL http://docs.call-logger.com:8090/download/attachments/4817104/nec_aspire_2.png - Within In the Site Properties window, select NEC Aspire from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the button to apply the settings.