These instructions help you configure your BT Versatility to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1BT Versatility.TDT
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPBX
Requiredtask2Configure TIM Plus
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

The BT Versatility outputs its SMDR data via a serial port. The default communication parameters for this serial connection are:

  • Speed – 4800, 9600, 19200, 38400 or 115200 bps;
  • Data - 8 bits;
  • Parity - None.

The phone system has an in-built buffer to store the last 500 call records in case the receiving equipment becomes disconnected. This buffered data can be set to output to the serial port during system programming. An

Referencemacro
LabelX-ON/X-OFF
 signal can be enabled to allow the Versatility to detect if a compatible device is receiving its SMDR data successfully. The Versatility can also be set to output SMDR data using
Referencemacro
Labelrestricted call logging
, whereby the last four digits of any dialled number is masked out.

Follow the instructions below to configure your BT Versatility for use with TIM Plus:

Screenshotmacro
Borderfalse
Shadowfalse
URL/download/attachments/4817052/bt_versatility_1.png

Screenshotmacro
Borderfalse
Shadowfalse
URL/download/attachments/4817052/bt_versatility_2.png

Screenshotmacro
Borderfalse
Shadowfalse
URL/download/attachments/4817052/bt_versatility_3.png

HTML
<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and follow the steps below:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817052/bt_versatility_4.png
  3. In the Site Properties window, select BT Versatility from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.