Configure the SMDR output

The SMDR output in LG iPECS is disabled by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.. To enable the output, you need to amend the following settings in the programming sections below:

SMDR Attributes (PGM 177)

Within this window you need to set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.

...

FieldDescription
Save EnableLeave this as the default which is unticked
Print EnableThis needs to be enabled by clicking on the check box
SMDR Record Call TypeThis needs to be set to 'All Calls', you will need to select this from the drop-down list
Records In DetailThis needs to be enabled by clicking on the check box
Print Incoming CallThis needs to be enabled by clicking on the check box
Print Lost CallThis needs to be enabled by clicking on the check box
SMDR Dial Digit HiddenLeave this as the default which is '0'
SMDR Currency UnitLeave this as the default which is blank
SMDR Cost Per Metering PulseLeave this as the default which is blank
SMDR FractionLeave this as the default which is '0'
SMDR Start TimeLeave this as the default which is '0'
SMDR Hidden DigitLeave this as the default which is 'Right'
Long Distance Call Digit CounterLeave this as the default which is '0'
Long Distance Code (Max 2 Digits)Leave this as the default
MSN Print on SMDRLeave this is the default which is unticked
Print Caller NumberThis needs to be enabled by clicking on the check box

Here is an example of a populated SMDR Attributes screen:

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817110/lg_ipecs_1.png

Printer Port Selection (PGM 175)

Below is an example of the Programming Port Selection window:

ScreenshotmacroURLhttp://docs.call-logger.com:8090/In the 

Referencemacro
LabelPrinter Port Selection (PGM 175)
window, set Info/On-line SMDR to COM1/COM2 to send call logging data by serial port.

ISDN Attributes (PGM 200)

To enable CLI information in the call records produced by your LG iPECS, you need to set the

Referencemacro
LabelCLI Print To Serial
 to
Keywordmacro
LabelON
, as shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817110/lg_ipecs_2.png

...

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

...

Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply perform the following settingssteps:

  1. Click on the Directory tab.
  2. Click on Choose the site configured during the setup wizard you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817110/lg_ipecs_43.png
  3. Within In the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.