...
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR
...
output
Follow the steps below to configure the SMDR output on the your NEC XN120. The programming will need to be done via PC Pro/Web Pro:
- Login Log in to your PC Pro/Web Pro software.
As the NEC XN120 has multiple ways of sending SMDR Data, below are the configuration settings based on each adaptor:
AdaptorTo configure SMDR output using an IP connection, apply the following settings:
Adapter Programming code Value Description NTCPU - IP 10-12-01 IP address that TIM Plus will connect to. NTUCPU Network Setup - IP Address. 10-20-01 TCP port that TIM Plus will connect to. We recommend using 9000 and increment incrementing it for each NEC XN120 you configure. LAN Setup for External Equipment. NTCPU - Serial 10-21-02 1 NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(38400). 35-01-01 1 SMDR Options - Output Port Type. You also need to configure the following programming codesApply the following settings in the programming sections below:
Programming code Value Description 14-01-06 1 Basic Trunk Data Setup - SMDR Print. 15-01-03 1 Basic Extension Data Setup - SMDR Print. 35-01-03 0 SMDR Options - Header Language. 35-01-04 0 SMDR Options - Omit (Mask) Digits. 35-01-05 0 SMDR Options - Minimum Number of SMDR Digits. 35-01-06 0 SMDR Options - Minimum Call Duration. 35-01-07 0 SMDR Options - Minimum Ringing Time. 35-01-08 Default SMDR Options - SMDR Format. 35-02-01 0 SMDR Output Options - Toll Restricted Call. 35-02-02 1 SMDR Output Options - PBX Calls. 35-02-03 1 SMDR Output Options - Display Trunk Name or Numbers. 35-02-04 0 SMDR Output Options - Daily Summary. 35-02-05 0 SMDR Output Options - Weekly Summary. 35-02-06 0 SMDR Output Options - Monthly Summary. 35-02-08 1 SMDR Output Options - Incoming calls. 35-02-09 0 SMDR Output Options - Print Name or Numbers. 35-02-10 0 SMDR Output Options - All Lines Busy (ALB) Output. 35-02-12 0 SMDR Output Options - DID Table Name Output. 35-02-13 1 SMDR Output Options - CLI Output when DID to Trunk. 35-02-14 1 SMDR Output Options - Date. 35-02-15 1 SMDR Output Options - CLI/DID Number Switching. 35-02-16 1 SMDR Output Options - Print Trunk Name or Received Dialled Number. 35-02-17 0 SMDR Output Options - Print Account Code or Caller ID Name. 35-02-18 Default SMDR Output Options - Caller ID Name Output Method. 80-05-01 1 Date Format for SMDR and System Reports.
...
Configuring TIM Plus
If your NEC Aspire XN120 has been configured to send the data via TCP/IPits SMDR data using an IP connection, follow the steps below to configure TIM Plus:
- Log on to TIM Plus as usual and click on Click on the tab.
- Click on Choose the site configured during the setup wizard you want to configure and click .
Screenshotmacro Border false URL http://docs.tri-line.com:8090/download/attachments/12583311/nec_xn120_1.png - Within In the Site Properties window, select NEC DXE from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP Address address of your NEC XN120.
- In the Port field, enter in enter the port number you configured in whilst programming code 10-20-01.
- Leave the Username and Password fields blank.
- In the Connection script field, select Generic Simple from the drop-down list.
- Finally, click Click on the button to apply the settings.