Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

To collect the call logging data from the Avaya BCM up to v3.x phone system and send it to TIM Plus, you first need to install the NetPBX software.

After the installation, click on follow the link instructions below for instructions on how to connect NetPBX with your BCM:

Connecting BCM v3.7 or below with NetPBX

to set up a connection between BCM and NetPBX:

  1. Make sure the CDRServer.EXE and Interop.CDRSERVERLib.dll files are placed in the same folder as NetPBX.EXE, usually located in {pf}\Tri-Line\NetPBX.
    Screenshotmacro
    URL/download/attachments/10321941/bcm_1.png
  2. Register CDRServer.EXE by running the command line with administrator privileges and typing the following command under the directory path of the NetPBX folder: CDRServer.EXE/regserver.
  3. Open the computer's local security policies: Start -> Control Panel -> Administrative Tools -> Local Security Policy.
    Screenshotmacro
    URL/download/attachments/10321941/bcm_2.png
  4. Within the 
    Referencemacro
    LabelSecurity Settings\Local Policies\Security Options
    tree, change the following items as highlighted in the screenshot below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/10321941/bcm_3.png

    1. Network Access: Let Everyone permissions apply to anonymous users. Set this to Enabled.
    2. Network Access: Sharing security model for local accounts. Set this to Classic.
    3. DCOM: Machine Access Restrictions: Click on Edit Security and add the following user accounts:
      Referencemacro
      LabelAnonymous, Everyone, Interactive, Network, System
      . Set each one to have full access rights.
      Screenshotmacro
      Borderfalse
      Shadowfalse
      URL/download/attachments/10321941/bcm_4.png
  5. Next step is to modify the way DCOM behaves on the computer by executing the DCOM configuration program: Start -> Run -> DCOMCNFG [enter]. Browse the tree to the following location: 
    Referencemacro
    LabelConsole Root -> Component Services -> Computers -> My Computer
    . Right-click on My Computer for Properties and amend or update the following options:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/10321941/bcm_5.png

    1. On the Default Properties tab:
      Enable Distributed COM on this computer: tick the box for his option
      Default Authentication Level: set this to Connect
      Default Impersonation Level: set this to Identify
      Screenshotmacro
      Borderfalse
      URL/download/attachments/10321941/bcm_6.png
    2. On the COM Security tab:
      Go to the Access Permissions section and select Edit default.
      Add the following accounts and set both local and remote access permissions: 
      Referencemacro
      LabelAnonymous, Everyone, Interactive, Network, Local Service
      and
      Referencemacro
      LabelSystem
      .
      Screenshotmacro
      Borderfalse
      Shadowfalse
      URL/download/attachments/10321941/bcm_7.png

      Go to the Launch and Activation Permissions section and click on Edit default tab.
      Add or update the following accounts to give them all local and remote access permissions: 
      Referencemacro
      LabelAnonymous, Everyone, Interactive, Network, Local Service
        and
      Referencemacro
      LabelSystem
      .
      Screenshotmacro
      Borderfalse
      Shadowfalse
      URL/download/attachments/10321941/bcm_8.png


HTML
<a id="Configure TIM Plus"></a>

...

  1. Log in to TIM Plus and click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817068/avaya_bcm_1.png
  3. In the Site Properties window, select Avaya BCM from the PBX model drop-down list.
  4. In the Connection method field, select  No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.