HTML |
---|
<p>These instructions should assist in configuring your Aastra BP to
work with TIM Enterprise. If you are not familiar with PBX
configuration, please contact your system maintainer.</p>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>Connection information</th>
<th class="confluenceTh">Description</th>
</tr>
<tr>
<td class="confluenceTd"><b>Connection type</b></td>
<td class="confluenceTd"><b>Serial Output or IP: </b>
If you have configured the LG iPECS to send the SMDR information via a serial connection, you will need to directly connect a serial cable from the LG iPECS to the PC that NetPBX is installed and running on.
</td>
</tr>
<tr>
<td class="confluenceTd"><b>Cable configuration</b></td>
<td class="confluenceTd">Null-modem/Crossover.
</td>
</tr>
<tr>
<td class="confluenceTd"><b>IP method</b></td>
<td class="confluenceTd">If the LG iPECS is configured to send the SMDR information via TCP/IP, the actual installation of TIM Enterprise can be anywhere on the network that the PBX is connected to. The LG iPECS
will need to be configured to output SMDR data via TCP/IP so TIM Plus can connect to it. TIM Enterprise will connect to the LG iPECS on TCP port 23.
</td>
</tr>
</tbody>
</table>
<h2>Configuring your SMDR</h2>
<p>The LG iPECS by default has SMDR output disabled. Below you will find
the programming number codes and the fields that need to be configured.</p>
<h4>PGM 177: SMDR Attributes</h4>
<p>Within this window you need set <span class="reference">Info/On-line SMDR</span> to <span class="keyword">Telnet 1</span>.
This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.</p>
<p>Below is an example <span class="reference">SMDR Attributes</span> window:</p>
<img id="border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/lg_ipecs_1.png" alt="LG iPECS" />
<h4>PGM 175: Printer Port Selection</h4>
<p>Below is an example <span class="reference">Programming Port Selection</span> window:</p>
<img id="border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/lg_ipecs_2.png" alt="LG iPECS" />
<h2>Configuring TIM Enterprise</h2>
<p>Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your LG iPECS:</p>
<ol>
<li>Browse to TIM Enterprise as normal and login with your credentials.</li>
<li>Click on the <span class="button" id="list">Directory</span> tab.</li>
<li>Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'LG iPECS'.</li>
<li>Left-click on it and select <span class="button" id="list">Properties</span>.</li>
<li>From the <span class="button" id="list">General</span> settings tab select <span class="keyword">LG iPECS</span> from the PBX model list.</li>
<img src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/lg_ipecs_3.png" alt="LG iPECS" />
<li>In the <span class="button" id="list">Connection</span> tab select <span class="keyword">Establish TCP connection to PBX</span> from the <span class="reference">Connection method</span> list.</li>
<li>In the <span class="reference">Host</span> field enter the IP Address of your LG iPECS.</li>
<li>Leave <span class="reference">Port</span> field blank.</li>
<li>Leave the <span class="reference">Username</span> field blank but enter the <span class="reference">Password</span>.</li>
<li>In the <span class="reference">IP script</span> field select <span class="keyword">Generic Simple</span> from the drop-down list.</li>
<li>Finally, click on the <span class="button" id="list">Save</span> button.</li>
<img src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/lg_ipecs_4.png" alt="LG iPECS" />
</ol> |
The LG iPECS can be configured to send its SMDR data over a serial (RS232) or an IP connection. Click on one of the links below that relates to your preferred connection method.