These instructions help you configure your SpliceCom your Splicecom Maximiser phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1SpliceCom Maximiser.TDT
Supportfiles2SpliceCom Maximiser.TDS
ConnectionActive connection
RequiredTask1Configure the SMDR output
RequiredTask2Configure TIM Plus

...

HTML
 

Confiure the SMDR output

...

<a id="Configure the SMDR output"></a>

Configuring the SMDR output

By default, the call logging output of the Splicecom Maximiser is enabled and you do not normally require a password to obtain it.  To protect your call logging data, you can set a

Referencemacro
LabelCall Logging Password
password has been set up in the phone system and if so, you will  in the 
Referencemacro
LabelSystem Details
 screen of your Maximiser's web management interface.  If you decide to set a password, you need to enter this in when configuring TIM Plus to enable the connection(below).

 

HTML
<p>These instructions should assist in configuring your SpliceCom Maximiser to 
work with TIM Plus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd">IP
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>IP method</b></td>
			<td class="confluenceTd"><b>TCP/IP connection: </b>
				The SpliceCom Maximiser sends SMDR information via TCP/IP on port 4001. TIM Plus will connect to the IP address of SpliceCom Maximiser.
			</td>
		</tr>
	</tbody>
</table>

<p>By default the SMDR output on the SpliceCom Maximiser is enabled. Please check with your system maintainer if they have added a 'Call Logging' password. If they have, they will need to tell 
you what it is as TIM Plus will require it when it connects.</p>

<h2>Configuring TIM Plus</h2>

<p>Below you will find steps on how to configure TIM Plus to connect to your SpliceCom Maximiser to receive SMDR:</p>

<ol>
	<li>Browse to TIM Plus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/splicecom_maximiser_1.png" alt="SpliceCom Maximiser" />
	<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">SpliceCom Maximiser</span> from the <span class="reference">PBX model</span> drop-down list.</li>
	<li>In the <span class="reference">Connection method</span> field select <span class="keyword">Actively connect to PBX</span> from the drop-down list.</li>
	<li>In the <span class="reference">Host</span> field enter the IP Address of your SpliceCom Maximiser.</li>
	<li>In the <span class="reference">Port</span> field enter in <span class="keyword">4001</span>.</li>
	<li>Leave the <span class="reference">Username</span> and <span class="reference">Password</span> fields blank.</li>
	<li>In the <span class="reference">Connection script</span> field select <span class="keyword">SpliceCom Maximiser</span> from the drop-down list.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol>
Info

Your system maintainer may have already set a call logging password for you.

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Follow the steps below to configure TIM Plus to collect call logging data from your Splicecom Maximiser:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    URL/download/attachments/4817032/splicecom_maximiser_1.png
  3. In the Site Properties window, select Splicecom Maximiser from the PBX model drop-down list.
  4. In the Connection method field, select Actively connect to PBX from the drop-down list.
  5. In the Host field, enter the IP address of your Splicecom Maximiser.
  6. In the Port field, enter 4001.
  7. Leave the Username field blank.
  8. If your Maximiser has a
    Referencemacro
    Labelcall logging password
     set, enter it in the Password field; if not, leave it blank.
  9. In the Connection script field, select Splicecom Maximiser from the drop-down list.
  10. Click on the Save button to apply the changes.