Pbxsummary
Supportfiles1Avaya Matra 6500.TDT
Supportfiles2Avaya Matra 6500.TDS
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPBX
Requiredtask2Configure TIM Plus
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

The Avaya Matra 65xx series is outputting the SMDR data via a serial connection. You will need to directly connect a serial cable from the between your Avaya Matra 65xx phone system to a PC that will be running NetPBX software.and the PC running netpbx. For more information about the output and configuration of the SMDR data, please contact your phone system maintainer.

HTML
<a id="infoInstall NetPBX"></a>

Installing NetPBX

...

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply perform the following settingssteps below:

  1. Click on the Directory tab.
  2. Click on Choose the site configured during the setup wizard and clickyou want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817075/avaya_matra_6500_1.png
  3. Within In the Site Properties window, select Avaya Matra 6500 from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

 

HTML
</hr>
<p>These instructions should assist in configuring your Avaya Matra 65xx series to 
work with TIM Plus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output: </b>
				Avaya Matra 65xx series PBX sends SMDR information via a serial connection. You will need to directly connect a serial cable from the Avaya Matra 65xx series PBX to the PC that NetPBX is installed and running on.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Null-modem/Crossover or Straight-through. Please check your Avaya Matra 65xx manual.
			</td>
		</tr>
	</tbody>
</table>

<h2>Configuring TIM Plus</h2>

<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Avaya Matra 6500:</p>

<ol>
	<li>Browse to TIM Plus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/avaya_matra_6500_1.png" alt="Avaya Matra 6500" />
	<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">Avaya Matra 6500</span> from the <span class="reference">PBX model</span> drop-down list.</li>
	<li>In the <span class="reference">Connection method</span> field select <span class="keyword">No connection required</span> from the drop-down list.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>