Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The input-configuration screen will be displayed. For information on how to configure these settings, refer to the Configuring an input section below.

Screenshotmacro
Borderfalse
Shadowfalse
URL/download/attachments/12588757/add_input_3.png

...

The

Referencemacro
LabelName
field allows you to view or edit the name of the selected input. To rename, overtype the current entry.

Selection_macro
ValueTest
SelectionName

Type

The

Referencemacro
LabelType
field allows you to specify the connection method you want to use to collect the data from the phone system. The following connection methods are supported in NetPBX:

Selection_macro
ValueSerial port
SelectionType

HTML
<a id="Input types"></a>

...

This method creates a socket and binds it to a specific port, accepting any data received on the connection without challenge.

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_listener.png

...

This method allows the connection of a serial (RS-232) device.

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_serial.png

...

This method creates a TCP socket and connects to a remote host. 

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_client_socket.png

FieldDescription
AddressThe IP address or hostname to which the socket should connect
Address familyThe address family of the socket
PortThe port that the listener should bind to
UsernameThe username required by the data source, if applicable
PasswordAn optional password which is sent upon successful connection
IP script The script file used by NetPBX to check for new data

Trickle frequency

 

Trickle data 

This option allows you reset the connection between NetPBX and remote host, in case of inactivity. When the system becomes inactive, NetPBX sends a string of data back to the remote host in order to test the connection. Sending the trickle back data will emit a detectable error in case a disconnection has occurred and, thus, will cause the connection to reset.

The

Referencemacro
LabelTrickle frequency
option allows you to configure the amount of inactivity that must occur (in miliseconds) before a trickle back is performed.

Trickle dataA string containing the data to be sent back

Pipe server

This method opens a global named pipe and accepts any data that is sent to it.

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_pipe_server.png

...

This method registers a connection with the 

Referencemacro
LabelNortel CDRClient.dll
library and receives data-callbacks whenever the PBX produces data.

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_BCM_SSH.png

FieldDescription
Host
The IP address or hostname of the BCM PBX
Username
The username required to access the CDR events
PasswordThe password required to access the CDR events
App IDThe unique ID number given to each source of data.

XML file

This method monitors an XML file for new nodes. To specify which nodes to monitor, an XPath query is used; to identify which nodes are new, a unique element is required. Default properties are designed to work with the ticketcollector.xml file produces by an Alcatel OmniPCX Enterprise PBX.

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_XML_file.png

FieldDescription
Location
The full filename of the XML file to be monitored. The {app} variable can be used to specify the program data location of the running service
X-Path query
The XPath query to use when testing for new nodes
Checksum nodeThe unique node(element) to be used to track which nodes have been added since the last check
Outer element

The name of the outer XML element to be used to contain any new nodes when the new XML document is created for output

Check interval The time interval the system is checking for a new node.

DelayA value, in milliseconds, that specifies the artificial delay that is waited when a change in the source XML file is discovered.

...

This method opens a connection to an actual file

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_file_reader.png

FieldDescription
Location
The path of the folder where the file is located

 

BCM DCOM

Screenshotmacro
Borderfalse
URL/download/attachments/12588757/input_BCM_DCOM.png

...

Screenshotmacro
Borderfalse
Shadowfalse
URL/download/attachments/12588757/delete_input.png