hese These instructions help you configure your Nortel/Avaya BCM (v4.0+) phone system version 4.x+ to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR
...
output
Follow the steps below to configure your Nortel/Avaya BCM v4.x+ to output SMDR data to TIM Plus:
- Login Log in to the BCM Element Manager.
- On the Task Navigation Panel, click the tab.
- Click on .
Click on .
- On the right-hand side the Call Detail Recording window will appear.
In the Call Detail Recording window panel that appears, configure the options as below:
SMDR field Value Format Norstar Report Type All Language English Date Format MM/DD/YY Header Format Line/Station Filter Type All Feature Code F9 Leave as default Minimum Call Duration Leave as default Hospitality Records Leave as default Include DNIS Info Enable Include CLID with call type Enable Include Long CLID Leave as default Use answer supervision Leave as default Display connection character Leave as default Suppress digits after connect Leave as default Maximum digits after connect Leave as default
HTML |
---|
<a id="Configure a CDR user"></a> |
CDR User
To enable TIM Plus to connect to
...
your Avaya BCM
...
, you
...
need to create a
...
Configuring TIM Plus
Below you will find steps on how
Referencemacro | ||
---|---|---|
|
Buttonmacro | ||
---|---|---|
|
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Follow the steps below to configure TIM Plus to collect the SMDR data from your Nortel/Avaya BCM:
- Log on in to TIM Plus and click on the tab.
- Click on Choose the site configured during the setup wizard you want to configure and click .
Screenshotmacro Border false URL http://docs.call-logger.com:8090/download/attachments/48170684817069/avaya_bcm_12.png - Within In the Site Properties window, select Avaya BCM from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP Address address of your Avaya BCM.
- In the Port field, enter in 4000.
- In the Username field, enter in CDR User.the username of the CDR user you configured in the BCM Unified Manager utility (above)
- In the Password field, enter in CDR User againthe password for the CDR user.
- In the Connection script field, select Avaya BCM v3v4 from the drop-down list.
- Click on the button to apply the settings.
HTML |
---|
<p>These instructions should assist in configuring your Avaya BCM to
work with TIM Plus. If you are not familiar with PBX
configuration, please contact your system maintainer.</p>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>Connection information</th>
<th class="confluenceTh">Description</th>
</tr>
<tr>
<td class="confluenceTd"><b>Connection type</b></td>
<td class="confluenceTd"><b>IP: </b>
The Avaya BCM v4.x+ CDR information is sent via TCP/IP. The actual installation of TIM Plus can be anywhere on the network that the PBX is connected to.
</td>
</tr>
<tr>
<td class="confluenceTd"><b>IP method</b></td>
<td class="confluenceTd">TIM Plus will connect to the IP address of your Avaya BCM v4.x+.
</td>
</tr>
</tbody>
</table>
<h2>Configuring your SMDR</h2>
<p>Below you will find instructions on how to configure your Avaya BCM v4.x+ to output SMDR to TIM Plus:</p>
<ol>
<li>Login to the BCM Element Manager.</li>
<li>On the <span class="reference">Task Navigation Panel</span>, click the <span class="button no_margin">Configuration</span> tab.</li>
<li>Click on <span class="button no_margin">Telephony</span>.</li>
<li>Click on <span class="button no_margin">Call Detail Recording</span>.</li>
<li>On the right-hand side the <span class="reference">Call Detail Recording</span> window will appear.</li>
<li>In the <span class="reference">Call Detail Recording</span> window, configure the options as below:</li>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=200>SMDR field</th>
<th class="confluenceTh">Value</th>
</tr>
<tr>
<td class="confluenceTd"><b>Format</b></td>
<td class="confluenceTd"><span class="keyword">Norstar</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Report Type</b></td>
<td class="confluenceTd"><span class="keyword">All</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Language</b></td>
<td class="confluenceTd"><span class="keyword">English</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Date Format</b></td>
<td class="confluenceTd"><span class="keyword">MM/DD/YY</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Header Format</b></td>
<td class="confluenceTd"><span class="keyword">Line/Station</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Filter Type</b></td>
<td class="confluenceTd"><span class="keyword">All</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Feature Code F9</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Minimum Call Duration</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Hospitality Records</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Include DNIS Info</b></td>
<td class="confluenceTd"><span class="keyword">Enable</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Include CLID with call type</b></td>
<td class="confluenceTd"><span class="keyword">Enable</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Include Long CLID</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Use answer supervision</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Display connection character</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Suppress digits after connect</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Maximum digits after connect</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
</tbody>
</table>
</ol>
<h4>CDR User</h4>
<p>For TIM Plus to connect to the Avaya BCM v4.x+ you will need to
create a <span class="reference">CDR User</span> on it. This can be done in the BCM Elements Manager
application, under the <span class="button">System</span> options.</p>
<h2>Configuring TIM Plus</h2>
<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Avaya BCM 4.0:</p>
<ol>
<li>Browse to TIM Plus as normal and login with your credentials.</li>
<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span> or create a new site and click <span class="button no_margin">Properties</span>.</li>
<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/avaya_bcm_2.png" alt="Avaya BCM 4.0" />
<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">Avaya BCM</span> from the <span class="reference">PBX model</span> drop-down list.</li>
<li>In the <span class="reference">Connection method</span> field select <span class="keyword">Actively connect to PBX</span> from the drop-down list.</li>
<li>In the <span class="reference">Host</span> field enter the IP Address of your Avaya BCM.</li>
<li>In the <span class="reference">Port</span> field enter in <span class="keyword">4000</span>.</li>
<li>In the <span class="reference">Username</span> field enter in <span class="keyword">CDR User</span>.</li>
<li>In the <span class="reference">Password</span> field enter in <span class="keyword">CDR User</span> again.</li>
<li>In the <span class="reference">Connection script</span> field select <span class="keyword">Avaya BCM v4</span> from the drop-down list.</li>
<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol> |