The SMDR output in LG iPECS is disabled by default. To To enable the output, you need to amend the following settings in the following programming codessections below:
SMDR Attributes (PGM 177)
Field | Description |
---|
Save Enable |
...
...
as the default which is unticked |
Print Enable |
...
| This needs to be enabled by clicking on the check box |
SMDR Record Call Type |
...
| This needs to be set to 'All Calls', you will need to select this from the drop-down list |
Records In Detail |
...
| This needs to be enabled by clicking on the check box |
Print Incoming Call |
...
| This needs to be enabled by clicking on the check box |
Print Lost Call |
...
| This needs to be enabled by clicking on the check box |
SMDR Dial Digit Hidden |
...
| Leave this as the default which is '0' |
SMDR Currency Unit |
...
| Leave this as the default which is blank |
SMDR Cost Per Metering Pulse |
...
| Leave this as the default which is blank |
SMDR Fraction |
...
| Leave this as the default which is '0' |
SMDR Start Time |
...
| Leave this as the default which is '0' |
SMDR Hidden Digit |
...
| Leave this as the default which is 'Right' |
Long Distance Call Digit Counter |
...
| Leave this as the default which is '0' |
Long Distance Code (Max 2 Digits) |
...
| Leave this as the default |
MSN Print on SMDR |
...
| Leave this is the default which is unticked |
Print Caller Number |
...
| This needs to be enabled by clicking on the check box
|
Here is an example of the a populated SMDR Attributes window screen:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817110/lg_ipecs_1.png |
---|
|
...
In the
Referencemacro |
---|
Label | Printer Port Selection (PGM 175) |
---|
|
window, set
Info/On-line SMDR to
Telnet 1 to allow connections on TCP port 23.Here is an example of the Programming Port Selection window COM1/COM2 to send call logging data by serial port.ISDN Attributes (PGM 200)
To enable CLI information in the call records produced by your LG iPECS, you need to set the
to , as shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817110/lg_ipecs_2.png |
---|
|
...
If your LG iPECS has been configured to send SMDR data via a serial connection, you first need to install the NetPBX netpbx software to collect the data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:
Install and configure NetPBX
HTML |
---|
<a id="Configure TIM Plus"></a> |
...
- Click on the Directory tab.
- Choose the site you want to configure and click Properties.
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817110/lg_ipecs_43.png |
---|
|
- In the Site Properties window, select LG iPECS from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the Save button to apply the settings.
...