HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR output
By default, the SMDR output of a Siemens HiCom/HiPath phone system is not enabled. Contact your system maintainer to enable it for incoming, outgoing and internal calls.
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Once NetPBX is configured and collecting data, log in to TIM Plus and perform the steps below:
- Click on the tab.
- Choose the site you want to configure and click
Screenshotmacro Border false URL /download/attachments/12583460/siemens_hicom_hipath_1.png . - In the Site Properties window, select Siemens HiCom-HiPath from the PBX model drop-down list.
- In the Connection method field, select Listen for connections from PBX from the drop-down list.
- Leave the Host field blank.
- In the Port field, enter 9000.
- Click on the . button to apply the settings