Configuring your SMDR
...
output
Info |
---|
Note that the GEC BTEX can output SMDR information in multiple formats. You should select the 600S format for use with TIM Plus. |
The GEC BTEX phone system sends SMDR information via a serial connection. You need to directly connect a serial cable from the GEC BTEX phone system to the PC that netpbx is installed and running on.
For more information about the output and configuration of your SMDR data, please contact your phone system maintainer.
HTML |
---|
<a id="infoInstall NetPBX"></a> |
Installing NetPBX
The GEC BTEX phone system sends SMDR information via a serial connection. To collect the call logging data from the serial port and send it to TIM Plus, you will first need to install the NetPBX software. For setup instructions, click on the link below:
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply perform the following settingssteps below:
- Click on the tab.
- Select Choose the site configured during the setup wizard you want to configure and click .
Screenshotmacro Border false URL http://docs.call-logger.com:8090/download/attachments/4817056/gec_btex_1.png - Within In the Site Properties window, select GEC BTEX 600S from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the button to apply the settings.
HTML |
---|
<hr/>
<p>These instructions should assist in configuring your GEC BTEX PBX to
work with TIM Plus. If you are not familiar with PBX
configuration, please contact your system maintainer.</p>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>Connection information</th>
<th class="confluenceTh">Description</th>
</tr>
<tr>
<td class="confluenceTd"><b>Connection type</b></td>
<td class="confluenceTd"><b>Serial Output: </b>
GEC BTEX PBX sends SMDR information via a serial connection. You will need to directly connect a serial cable from the GEC BTEX PBX to the PC that NetPBX is installed and running on.
</td>
</tr>
<tr>
<td class="confluenceTd"><b>Cable configuration</b></td>
<td class="confluenceTd">Null-modem/Crossover or Straight-through. Please check your GEC BTEX manual.
</td>
</tr>
</tbody>
</table>
<p>For your SMDR configuration, please note that GEC BTEX has multiple output formats. For TIM Plus, the output will need to be configured to the <span class="keyword">600S</span> format.</p>
<h2>Configuring TIM Plus</h2>
<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your GEC BTEX 600S:</p>
<ol>
<li>Browse to TIM Plus as normal and login with your credentials.</li>
<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li>
<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/gec_btex_1.png" alt="GEC BTEX 600S" />
<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">GEC BTEX 600S</span> from the <span class="reference">PBX model</span> drop-down list.</li>
<li>In the <span class="reference">Connection method</span> field select <span class="keyword">No connection required</span> from the drop-down list.</li>
<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol> |