Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Log in to your PC Pro/Web Pro software.
  2. To configure SMDR output using an IP connection, apply the following settings for each system adapter:

    AdapterProgramming codeValueDescription
    NTCPU - IP10-12-01IP address of the PC running that TIM Enterprise will connect to.NTUCPU Network Setup - IP Address.
    10-20-01TCP port that TIM Enterprise will connect to. We recommend using 9000 and incrementing it for each NEC Aspire you configure.LAN Setup for External Equipment.
  3. Apply the following settings in the programming sections below:

    Programming codeValueDescription
    14-01-061Basic Trunk Data Setup - SMDR Print.
    15-01-031Basic Extension Data Setup - SMDR Print.
    35-01-030SMDR Options - Header Language.
    35-01-040SMDR Options - Omit (Mask) Digits.
    35-01-050SMDR Options - Minimum Number of SMDR Digits.
    35-01-060SMDR Options - Minimum Call Duration.
    35-01-070SMDR Options - Minimum Ringing Time.
    35-01-08DefaultSMDR Options - SMDR Format.
    35-02-010SMDR Output Options - Toll Restricted Call.
    35-02-021SMDR Output Options - PBX Calls.
    35-02-031SMDR Output Options - Display Trunk Name or Numbers.
    35-02-040SMDR Output Options - Daily Summary.
    35-02-050SMDR Output Options - Weekly Summary.
    35-02-060SMDR Output Options - Monthly Summary.
    35-02-081SMDR Output Options - Incoming calls.
    35-02-090SMDR Output Options - Print Name or Numbers.
    35-02-100SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-120SMDR Output Options - DID Table Name Output.
    35-02-131SMDR Output Options - CLI Output when DID to Trunk.
    35-02-141SMDR Output Options - Date.
    35-02-151SMDR Output Options - CLI/DID Number Switching.
    35-02-161SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-170SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18DefaultSMDR Output Options - Caller ID Name Output Method.
    80-05-011Date Format for SMDR and System Reports

...

  1. Click on the Directory tab.
  2. Choose Locate the PBX object you want to configure and click in the Directory, right-click on it and select Properties.
  3. A new window will open. In the General tab, select , displaying the general properties of your PBX object. Select NEC Aspire from the Data format list and tick the the 
    Keywordmacro
    LabelKeep a local backup of data
    box, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/13271292/nec_aspire_1.png
  4. In Click on the Connection tab , and select Establish TCP connection to PBX from the Connection method list.
  5. In the Host field, enter the IP address of your NEC Aspire.
  6. In the Port field, enter the port number you configured whilst programming code 10-20-01 (above).
  7. Leave the Username and Password fields blank.
  8. In the IP script field, select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/13271294/nec_aspire_ip.png