These instructions help you configure your Avaya Network Alchemy to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus establishes a serial connection with this PBX.Support Files
Avaya Norstar.TDTAvaya Norstar.TDS
Required Tasks
$paramRequiredTask1Please contact our Technical Support team to obtain the Avaya Norstar support files: Avaya Norstar.TDT and Avaya Norstar.TDS.
Configuring your CDR
Below you will find instructions on how to configure your Avaya Norstar to output CDR to TIM Plus. You will need to do this from a system programming phone:
- On your programming phone, press the key and then to access the CLI menu.
- Press Printer and the current baud rate that the data is sent. If want to change this, select and select the new baud rate. and you will see
- Press Format. Select and set it to Norstar. and you will see
- Press Report. Please leave this as the default which is All. and you will see
- Now press the button as the programming is complete.
Installing NetPBX
The Avaya Norstar phone system sends SMDR information via a serial connection. To collect the data from the serial port, you will first need to install NetPBX software,which then sends the SMDR to TIM Plus. For setup instructions, click on the link below:
Configuring TIM Plus
Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:
- Click on the tab.
- Click on the site configured during the setup wizard and click
These instructions should assist in configuring your Avaya Norstar to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | Serial Output: The Avaya Norstar requires a CLI2 box. If you don't have one you should speak to your system maintainer to purchase one. Avaya Norstar PBX sends SMDR information via a serial connection. You will need to directly connect a serial cable from the CLI2 box to the PC that NetPBX is installed and running on. |
Cable configuration | Null-modem/Crossover. |
Configuring your CDR
Below you will find instructions on how to configure your Avaya Norstar to output CDR to TIM Plus. You will need to do this from a system programming phone:
- On your programming phone, press the key and then to access the CLI menu.
- Press Printer and the current baud rate that the data is sent. If want to change this, select and select the new baud rate. and you will see
- Press Format. Select and set it to Norstar. and you will see
- Press Report. Please leave this as the default which is All. and you will see
- Now press the button as the programming is complete.
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Avaya Norstar:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select Avaya Norstar from the PBX model drop-down list.
- In the Connection method field select No connection required from the drop-down list.
- Finally, click on the button.