These instructions help you configure your LG IPLDK phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Plus establishes a serial connection with this PBX.

Support Files
  LG IPLDK.TDT
  LG.TDS
Required Tasks
  $paramRequiredTask1
or
Connection Type
  TIM Plus establishes a TCP connection to this PBX.

Support Files
  LG IPLDK.TDT
  LG.TDS
Required Tasks
  $paramRequiredTask1

Configuring your SMDR

The LG IPLDK by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.

Print Serial Port Selection (PGM 175)

Within this window you need set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG IPLDK on TCP port 23 to receive SMDR data.

Below is an example of the Print Serial Port Selection window:


SMDR Attributes (PGM 177)

Below is an example of the SMDR Attributes window:


ISDN Attributes (PGM 200)

Below is an example of the ISDN Attributes window. Please note that the CLI Print to serial field needs to be enabled.


Serial output

 

Installing NetPBX

If your LG IPLDK has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.

  3. Within the Site Properties window, select LG IPLDK from the PBX model drop-down list.
  4. In the Connection method field select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

IP output

Configuring TIM Plus

If your LG IPLDK has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.

  3. Within the Site Properties window, select LG IPLDK from the PBX model drop-down list.
  4. In the Connection method field select Actively connect to PBX from the drop-down list.
  5. In the Host field enter the IP Address of your LG IPLDK.
  6. In the Port field enter in 23.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field select Generic Simple from the drop-down list.
  9. Finally, click on the Save button to apply the settings.


These instructions should assist in configuring your LG IPLDK to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.

Connection information Description
Connection type Serial Output or IP: If you have configured the LG IPLDK to send the SMDR information via a serial connection, you will need to directly connect a serial cable from the LG IPLDK to the PC that NetPBX is installed and running on.
Cable configuration Null-modem/Crossover.
IP method If the LG IPLDK is configured to send the SMDR information via TCP/IP, the actual installation of TIM Plus can be anywhere on the network that the PBX is connected to. The LG IPLDK will need to be configured to output SMDR data via TCP/IP so TIM Plus can connect to it. TIM Plus will connect to the LG iPECS on TCP port 23.

Configuring your SMDR

The LG IPLDK by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.

Print Serial Port Selection (PGM 175)

Within this window you need set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG IPLDK on TCP port 23 to receive SMDR data.

Below is an example of the Print Serial Port Selection window:

LG IPLDK

SMDR Attributes (PGM 177)

Below is an example of the SMDR Attributes window:

LG IPLDK

ISDN Attributes (PGM 200)

Below is an example of the ISDN Attributes window. Please note that the CLI Print to serial field needs to be enabled.

LG IPLDK

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to listen for SMDR data from your LG IPLDK:

  1. Browse to TIM Plus as normal and login with your credentials.
  2. Click on the Directory tab.
  3. Click on the site configured during the setup wizard and click Propertiesor create a new site and click Properties.
  4. LG IPLDK
  5. Within the Site Properties window, select LG IPLDK from the PBX model drop-down list.
  6. In the Connection method field select Actively connect to PBX from the drop-down list.
  7. In the Host field enter the IP Address of your LG IPLDK.
  8. In the Port field enter in 23.
  9. Leave the Username and Password fields blank.
  10. In the Connection script field select Generic Simple from the drop-down list.
  11. Finally, click on the Save button.