These instructions help you configure your Avaya BCM 4.x+ phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus establishes a TCP connection to this PBX.Support Files
Avaya BCM.TDTAvaya BCM.TDS
Required Tasks
Configure the SMDR outputConfigure a CDR user
Configure TIM Plus
Configuring your SMDR
Below you will find instructions on how to configure your Avaya BCM v4.x+ to output SMDR to TIM Plus:
- Login to the BCM Element Manager.
- On the Task Navigation Panel, click the tab.
- Click on .
- Click on .
- On the right-hand side the Call Detail Recording window will appear.
In the Call Detail Recording window, configure the options as below:
SMDR field Value Format Norstar Report Type All Language English Date Format MM/DD/YY Header Format Line/Station Filter Type All Feature Code F9 Leave as default Minimum Call Duration Leave as default Hospitality Records Leave as default Include DNIS Info Enable Include CLID with call type Enable Include Long CLID Leave as default Use answer supervision Leave as default Display connection character Leave as default Suppress digits after connect Leave as default Maximum digits after connect Leave as default
CDR User
To enable TIM Plus to connect to your Avaya BCM v4.x+, you will need to create a CDR User in your phone system. This can be configured within your Business Communications Manager Unified Manager appliction, under the options.
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to collect the SMDR data from your Avaya BCM:
- Log on to TIM Plus and click on the tab.
- Click on the site configured during the setup wizard and click
. - Within the Site Properties window, select Avaya BCM from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host fiel,d enter the IP Address of your Avaya BCM.
- In the Port field, enter in 4000.
- In the Username field, enter in CDR User.
- In the Password field, enter in CDR User again.
- In the Connection script field, select Avaya BCM v3 from the drop-down list.
- Click on the button to apply the settings.