These instructions help you configure your Avaya Communications Manager phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Plus listens for connections from this PBX.

Support Files
  Avaya Communications Manager.TDT
  Avaya Communications Manager.TDS
Required Tasks
  $paramRequiredTask1

Configuring your Avaya Communications Manager

Configuring node-names ip

You will need to use the change node-names command to add a new node. You will have two fields which are required to be populated:

  • Name: In this field please enter in TIMPlus.
  • IP Address: This needs to be set to the IP Address of the machine that TIM Plus is installed on.

Below you can find an example of node-names configuration:


Configuring ip-services

You will need to use the change ip-services command to add/ammend ip-services. There are three pages that need to be configured, below you will find, by page the fields that need to be configured.

In Page 1, you will have the following fields which are required to be populated:

  • Service type: This needs to be set to CDR1.
  • Local Node: This needs to be set to the node-name of the CLAN board.
  • Local Port: This cannot be changed, it is always set to 0.
  • Remote Node: This needs to be set to the node-name which was created in the node-names section which should be TIMPlus.
  • Remote Port: This is the TCP port that TIM Plus will be listening on. Generally the 9000 range is normally free so we could recommended you select one from there.

Below you can find an example of ip-services configuration, Page 1:


In Page 2, no configuration changes are needed.

In Page 3, you will have the following fields which are required to be populated:

  • Reliable Protocol: This needs to be set to n.
  • Packets Resp Timer: Please leave this as the default, which is 30.
  • Sessions Connect Message Cntr: Please leave this as the default, which is 3.
  • SPDU Cntr: Please leave this as the default, which is 3.
  • Connectivity Timer: Please leave this as the default, which is 60.

Below you can find an example of ip-services configuration, Page 3:


Configuring system-parameters cdr

You will need to use the change system-parameters cdr command to amend the CDR format. As there are quite a few changes, we have supplied screenshots of each page and how it should be configured.

Below you can find Page 1 of system-parameters cdr configuration:


Page 2 of system-parameters cdr configuration is as shown below:


Configuring trunk-group

To receive response times for incoming calls, you need to set the CDR field for each trunk group to r. You will need to use the change trunk-group X, 'X' being the trunk group number.

Below you can find an example of trunk-groups configuration:


Configuring intra-switch-cdr

To receive internal calls CDRs you will need to populate the intra-switch-cdr table with the extension numbers that you want to see the internal calls for. You will need to use the change intra-switch-cdr command.

Below you can find an example of the intra-switch-cdr configuration:


Configuring multiple Avaya Communications Managers

If you have multiple sites where you have more than one Avaya Communications Manager, configuring the CDR output can vary depending on the setup. The two scenarios are explained below:

  • Avaya Communications Manager - LSPs (Local Survivable Processors)
    If all of your Avaya Communications Managers are connected and the remote sites are 'LSPs' then you only need to configure the Master/Primary Avaya Communications Manager. When TIM Plus receives the CDR information, it will include all of the CDRs from the remote LSPs.
  • Avaya Communications Manager - Not linked
    If you have multiple Avaya Communications Managers where LSP isn't being used, you will need to configure each Avaya Communications Manager separately. You will need to make sure that each Avaya Communications Manager has its own unique Remote Port (IP-services) setup.

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Avaya Communications Manager:

  1. Browse to TIM Plus as normal and login with your credentials.
  2. Click on the Directory tab.
  3. Click on the site configured during the setup wizard and click Properties.

  4. Within the Site Properties window, select Avaya Communications Manager from the PBX model drop-down list.
  5. In the Connection method field, select Listen for connections from PBX from the drop-down list.
  6. Leave the Host field blank.
  7. In the Port field, enter in the Remote Port (ip-services) that was configured on your Avaya Communication Manager.
  8. Click on the Options tab and tick the box Timestamp received data.

  9. Finally, click on the Save button to apply the settings.

 

 