These instructions help you configure your Cisco UCME / UC500 to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus captures SysLog packets from this PBX.Support Files
Cisco UCME - SysLog.TDTCisco UCME - SysLog.TDS
Required Tasks
Configure UCME to send SysLog eventsConfigure Cisco AXL sync
Configure TIM Plus to capture SysLog packets
Configuring UCME to send SysLog events
Login to your Cisco UCME / UC500 via telnet, as shown below:
Now just enter the following SysLog commands:
Step | IOS commands | Description |
---|---|---|
1 | enable | Enter EXEC mode, enter password if requested. |
2 | conf t | Enter global configuration mode. |
3 | aaa new-model | Enable aaa accounting mode. |
aaa accounting connection h323 start-stop group SysLog | ||
gw-accounting syslog | ||
acct-template callhistory-detail | ||
4 | logging 192.168.1.1 | Specifies the IP address to send CDR data. Where '192.168.1.1' is the machine running TIM Plus. |
5 | end | Exit configuration mode. |
6 | wr | Save changes. |
Configuring Cisco AXL sync
Below you will find steps on how to configure the Directory Sync from Cisco UCM:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select the tab.
- Click on the Synchronise with the following device tick box.
- In the Host field enter in the IP Address of your UCME / UC500.
- In the Username field enter in the username to login to your UCME / UC500.
- Click on the button and enter the password used to login to the UCME / UC500, followed by clicking .
- Finally, click on the button.
Configuring TIM Plus to capture SysLog packets
Below you will find steps on how to configure TIM Plus to receive data from your Cisco UCM:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Select the site configured during the setup wizard and click
. - Within the Site Properties window, select Cisco UCME - SysLog from the PBX model drop-down list.
- In the Connection method field, select SysLog connection from the drop-down list.
- In the Client IP field, enter in the IP Address of the Cisco UCME / UC500.
- Finally, click on the button to apply the settings.