These instructions help you configure your Alcatel OmniPCX Enterprise phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Plus establishes a serial connection with this PBX.

Support Files
  Alcatel OmniPCX Enterprise.TDT
  Alcatel OmniPCX Enterprise.TDS
Required Tasks
  Configure the SMDR output
  Install NetPBX
  Configure TIM Plus

Configuring your SMDR output

Follow the instructions below to configure the SMDR output via a serial connection. These instructions are taken from the Alcatel OmniPCX Enterprise manual:

Connect to your PBX via telnet and follow the steps below:

  1. Applications (Enter)
  2. Accounting (Enter)
  3. Review/Modify (Enter)
  4. All Instance (F1)
  5. Realtime ticket Output: Set this to ethernet. Note that if you don't have an appropriate license you may only select V24 (serial) here.
  6. Save changes and exit.

Below is an example of the data output from an Alcatel OmniPCX Enterprise:


Installing NetPBX

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:

  1. Click on the Directory tab.
  2. Select the site you configured during the setup wizard and click Properties.

  3. Within the Site Properties window, select Alcatel OmniPCX Enterprise from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

 

 

Labels: