These instructions help you configure your GEC BTEX phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Enterprise establishes a serial connection with this PBX.Support Files
GEC BTEX 600S.TDTRequired Tasks
Configure the SMDR outputInstall NetPBX
Configure TIM Enterprise
Configuring your SMDR output
Note that the GEC BTEX can output SMDR information in multiple formats. You should select the 600S format for use with TIM Plus. |
The GEC BTEX phone system sends SMDR information via a serial connection. You need to directly connect a serial cable from the GEC BTEX phone system to the PC that NetPBX is installed and running on. For more information about the output and configuration of your SMDR data, please contact your system maintainer.
Installing NetPBX
To collect the call logging data from the serial port and send it to TIM Plus, you first need to install the NetPBX software. For setup instructions, click on the link below:
Configuring TIM Enterprise
Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:
- Click on the tab.
- Choose the PBX object you want to configure and click Properties.
- A new window will open. In the GEC BTEX 600S from the Data format list and tick the Keep a local backup of data box, as shown below:
tab, select - In the No connection required from the Connection method list. tab, select
- Click on the
button to apply the settings.
These instructions should assist in configuring your GEC BTEX PBX to work with TIM Enterprise. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | Serial Output: GEC BTEX PBX sends SMDR information via a serial connection. You will need to directly connect a serial cable from the GEC BTEX PBX to the PC that NetPBX is installed and running on. |
Cable configuration | Null-modem/Crossover or Straight-through. Please check your GEC BTEX manual. |
For your SMDR configuration, please note that GEC BTEX has multiple output formats. For TIM Enterprise, the output will need to be configured to the 600S format.
Configuring TIM Enterprise
Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your GEC BTEX 600S:
- Browse to TIM Enterprise as normal and login with your credentials.
- Click on the tab.
- Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'GEC BTEX 600S'.
- Left-click on it and select .
- From the GEC BTEX 600S from the PBX model list. settings tab select
- In the No connection required from the Connection method list. tab select
- Finally, click on the button.