You are viewing an old version of this page. View the current version.
Compare with Current ·
View Page History
These instructions should assist in configuring your BT Pathway to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | Serial Output: The BT Pathway sends SMDR information via a serial connection. The BT Pathway has a SMDR/V24 port on the base motherboard. The connection itself is RJ11 and you will need to purchase a V24/SMDR module from your system supplier/maintainer. |
Cable configuration | Straight-through. |
You will need to directly connect a serial cable from the V24/SMDR module to the PC that NetPBX is installed and running on.
Configuring your SMDR
To receive SMDR information from the BT Pathway you will need to have a BT SystemPhone. You will need to be familiar with programming via the BT SystemPhone. To enable the SMDR output follow the below steps:
- From the programming position, press the phone set up key P and select .
- Enter the PIN and select .
- Select and choose .
- Press to finish.
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your BT Pathway:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select BT Pathway from the PBX model drop-down list.
- In the Connection method field select No connection required from the drop-down list.
- Finally, click on the button.
Labels: