<p>These instructions should assist in configuring your BT Pathway to 
work with TIM Plus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output: </b>
				The BT Pathway sends SMDR information via a serial connection. The BT Pathway has a SMDR/V24 port on the base motherboard. The connection itself is RJ11 and you will need to purchase a 
				V24/SMDR module from your system supplier/maintainer.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Straight-through.
			</td>
		</tr>
	</tbody>
</table>

<p>You will need to directly connect a serial cable from the V24/SMDR module to the PC that NetPBX is installed and running on.</p>

<h2>Configuring your SMDR</h2>

<p>To receive SMDR information from the BT Pathway you will 
need to have a BT SystemPhone. You will need to be familiar with 
programming via the BT SystemPhone. To enable the SMDR output follow 
the below steps:</p>

<ol>
	<li>From the programming position, press the phone set up key <span class="button no_margin">P</span> and select <span class="button no_margin">System programming</span>.</li>
	<li>Enter the PIN and select <span class="button no_margin">System</span>.</li>
	<li>Select <span class="button no_margin">Call logging</span> and choose <span class="button no_margin">Call logging on</span>.</li>
	<li>Press <span class="button no_margin">HANDSFREE/MONITOR</span> to finish.</li>
</ol>

<h2>Configuring TIM Plus</h2>

<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your BT Pathway:</p>

<ol>
	<li>Browse to TIM Plus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/bt_pathway_1.png" alt="BT Pathway" />
	<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">BT Pathway</span> from the <span class="reference">PBX model</span> drop-down list.</li>
	<li>In the <span class="reference">Connection method</span> field select <span class="keyword">No connection required</span> from the drop-down list.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>