These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

or

Configuring your SMDR

The LG iPECS by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.

SMDR Attributes (PGM 177)

Within this window you need to set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.

Below is an example of the SMDR Attributes window:

Printer Port Selection (PGM 175)

Below is an example of the Programming Port Selection window:

Serial output

<a id="info"></a>
Installing NetPBX

If your LG iPECS has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.
  3. Within the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field select No connection required from the drop-down list
  5. Click on the Save button to apply the settings.

IP output

Configuring TIM Plus

If your LG iPECS has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.
  3. Within the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field select Listen for connections from PBX from the drop-down list.
  5. In the Host field enter in the IP Address of your LG iPECS.
  6. In the Port field enter in 23.
  7. Click on the Save button to apply the settings.
<hr/>
<p>These instructions should assist in configuring your LG iPECS to 
work with TIM Plus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output or IP: </b>
				If you have configured the LG iPECS to send the SMDR information via a serial connection, you will need to directly connect a serial cable from the LG iPECS to the PC that NetPBX is installed and running on.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Null-modem/Crossover.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>IP method</b></td>
			<td class="confluenceTd">If the LG iPECS is configured to send the SMDR information via TCP/IP, the actual installation of TIM Plus can be anywhere on the network that the PBX is connected to. The LG iPECS 
			will need to be configured to output SMDR data via TCP/IP so TIM Plus can connect to it. TIM Plus will connect to the LG iPECS on TCP port 23.
			</td>
		</tr>
	</tbody>
</table>

<h2>Configuring your SMDR</h2>

<p>The LG iPECS by default has SMDR output disabled. Below you will find 
the programming number codes and the fields that need to be configured.</p>

<h4>SMDR Attributes (PGM 177)</h4>

<p>Within this window you need to set <span class="reference">Info/On-line SMDR</span> to <span class="keyword">Telnet 1</span>.  
This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.</p>

<p>Below is an example of the <span class="reference">SMDR Attributes</span> window:</p>

<img class="screenshot" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/lg_ipecs_1.png" alt="LG iPECS" />

<h4>Printer Port Selection (PGM 175)</h4>

<p>Below is an example of the <span class="reference">Programming Port Selection</span> window:</p>

<img class="screenshot" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/lg_ipecs_2.png" alt="LG iPECS" />

<h2>Configuring TIM Plus</h2>

<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your LG iPECS:</p>

<ol>
	<li>Browse to TIM Plus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/lg_ipecs_3.png" alt="LG iPECS" />
	<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">LG iPECS</span> from the <span class="reference">PBX model</span> drop-down list.</li>
	<li>In the <span class="reference">Connection method</span> field select <span class="keyword">Listen for connections from PBX</span> from the drop-down list.</li>
	<li>In the <span class="reference">Host</span> field enter in the IP Address of your LG iPECS.</li>
	<li>In the <span class="reference">Port</span> field enter in <span class="keyword">23</span>.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol>