These instructions help you configure your Siemens HiPath 4000 phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configuring your SMDR output

The Siemens HiPath 4000 doesn't have the SMDR output enabled by default. Please contact your phone maintainer to enable the data output for incoming, outgoing and internal calls.

<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Select the site configured during the setup wizard and clickProperties.
  3. Within the Site Properties window, select Siemens HiCom-HiPath from the PBX model drop-down list.
  4. In the Connection method field select Actively connect to PBX from the drop-down list.
  5. In the Host field enter the IP Address of your Siemens HiPath 4000.
  6. In the Port field enter in 9000.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.
<p>These instructions should assist in configuring your Siemens HiPath 4000 to 
work with TIM Plus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd">IP
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>IP method</b></td>
			<td class="confluenceTd"><b>TCP/IP connection: </b>
				The Siemens HiPath 4000 sends SMDR information via TCP/IP on a TCP port. TIM Plus will connect to the IP address of Siemens HiPath 4000.
			</td>
		</tr>
	</tbody>
</table>

<p>For your SMDR configuration, you will need to speak to your system maintainer to enable SMDR output.</p>

<h2>Configuring TIM Plus</h2>

<p>Below you will find steps on how to configure TIM Plus to connect to your Siemens HiPath 4000 to receive SMDR:</p>

<ol>
	<li>Browse to TIM Plus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/siemens_hipath_4000_1.png" alt="Siemens HiPath 4000" />
	<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">Siemens HiPath 4000</span> from the <span class="reference">PBX model</span> drop-down list.</li>
	<li>In the <span class="reference">Connection method</span> field select <span class="keyword">Actively connect to PBX</span> from the drop-down list.</li>
	<li>In the <span class="reference">Host</span> field enter the IP Address of your Siemens HiPath 4000.</li>
	<li>In the <span class="reference">Port</span> field enter in <span class="keyword">9000</span>.</li>
	<li>Leave the <span class="reference">Username</span> and <span class="reference">Password</span> fields blank.</li>
	<li>In the <span class="reference">Connection script</span> field select <span class="keyword">Generic Simple</span> from the drop-down list.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol>