These instructions help you configure your Avaya BCM 4.x+ phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
<a id="Configure the SMDR output"></a> |
Below you will find instructions on how to configure your Avaya BCM v4.x+ to output SMDR to TIM Plus:
On the right-hand side the Call Detail Recording window will appear.
In the Call Detail Recording window, configure the options as below:
SMDR field | Value |
---|---|
Format | Norstar |
Report Type | All |
Language | English |
Date Format | MM/DD/YY |
Header Format | Line/Station |
Filter Type | All |
Feature Code F9 | Leave as default |
Minimum Call Duration | Leave as default |
Hospitality Records | Leave as default |
Include DNIS Info | Enable |
Include CLID with call type | Enable |
Include Long CLID | Leave as default |
Use answer supervision | Leave as default |
Display connection character | Leave as default |
Suppress digits after connect | Leave as default |
Maximum digits after connect | Leave as default |
<a id="Configure a CDR user"></a> |
To enable TIM Plus to connect to your Avaya BCM v4.x+, you will need to create a in your phone system. This can be configured within your Business Communications Manager Unified Manager appliction, under the options.