These instructions help you configure your Avaya BCM phone system up to v3.x to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
<a id="Configure the SMDR output"></a> |
Below you will find instructions on how to configure your Avaya BCM up to v3.x to output SMDR to TIM Plus:
Now on the left-hand side, click on
and configure the fields as per below:SMDR field | Value |
---|---|
Format | Norstar |
Report Type | All |
Language | English |
Report Filter | All |
On the left-hand side, click on
and configure the fields as per below:SMDR field | Value |
---|---|
Date Format | MM/DD/YY |
Header Format | Line/Station |
DNIS Info | Enabled |
Connection Char | Leave as default |
Clip File Schedule | Leave as default |
Clip File Size | Leave as default |
CDR Disk Space Limit | Leave as default |
<a id="Create a CDR user"></a> |
To enable TIM Plus to connect to your Avaya BCM v3.x, you will need to create a CDR User in your phone system. This can be configured within your Business Communications Manager Unified Manager appliction, under the options. The Avaya BCM v3.x connection requires TIM Plus to use the Microsoft DCOM object. As the Microsoft has increased the security in DCOM after Windows XP Service Pack 2, the username and password for the CDR User need to be exactly the same as the credentials for the Windows account.
<a id="Configure TIM Plus"></a> |
Below you will find steps on how to configure TIM Plus to collect the SMDR data from your Avaya BCM: